September 2016
B-10 Ins pec t and Lubric ate the Outri gger Lev eling J ack Footpads - AW PS Models
B-10
Inspect and Lubricate the
Outrigger Leveling Jack
Footpads - AWPS Models
Genie requires that this procedure be performed
every 250 hours or quarterly, whichever comes
first.
Detection of unusual wear of the leveling jack
footpads is essential for safe machine operation.
An improperly lubricated and or damaged footpad
could result in an unsafe condition.
1
Visually inspect the leveling jack footpads for
any unusual wear.
2
Liberally apply grease to the top of the
footpads at the swivel point and the leveling
jack threads.
1 outrigger leveling jack threads
2 outrigger footpad swivel point
3 outrigger footpad
Grease Type
Part No. 38139
B-11 T est the Level Sensing Operati on - IW PS Models
B-11
Test the Level Sensing Operation
- IWPS Models
Genie requires that this procedure be performed
every 250 hours or quarterly, whichever comes
first.
Detection of level sensing malfunctions is essential
for safe machine operation. An improperly
functioning level sensing system could result in
unsafe operating conditions.
1
2
3
4
5
6
Lithium-based
AWP Super Series • IWP Super Series
Checklist B Procedures
Position the machine on a firm, level surface
Turn the key switch to ground control and pull
out the red Emergency Stop button to the
position. Twist to release the red Emergency
Stop button at the platform controls.
Result: The power light should be on.
Adjust the leveling jacks until the bubble is in
the center ring of the bubble level and all four
foot pads are in firm contact with the ground.
Result: Within 1 to 4 seconds, all four interlock
display lights should turn on and remain on.
Pump the foot pedal to raise the base.
Place a ¼ inch / 6.35 mm thick spacer under
one adjustable and one non-adjustable foot
pad on the same side of the machine.
Pull the base lowering handle to fully lower the
base.
Result: Within 1 to 4 seconds, all four interlock
display lights should turn on and remain on.