Base Components Iwps Models - Genie AWP Super Series Service Manual

Hide thumbs Also See for AWP Super Series:
Table of Contents

Advertisement

Service Manual
Base Assembly
1-2 Base Com ponents IWPS Models
1-2

Base Components IWPS Models

How to Remove the Inner Base
Frame
Bodily injury hazard. This
procedure requires specific repair
skills, lifting equipment and a
suitable workshop. Attempting
this procedure without these skills
and tools could result in death or
serious injury and significant
component damage. Dealer
service is strongly recommended.
1
Pull the base lowering handle to fully lower the
base.
2
Attach an overhead crane to the lifting eye at
the top of the mast.
3
Remove the mounting fastener from the lift
cylinder rod end. Lift the rod end of the
cylinder up and attach it to the base.
4
Tag, disconnect and plug the three hydraulic
hoses from the base manifold. Cap the ports
on the manifold
Bodily injury hazard. Spraying
hydraulic oil can penetrate and
burn skin. Loosen hydraulic
connections very slowly to allow
the oil pressure to dissipate
gradually. Do not allow oil to
squirt or spray.
5
Pull the hoses through the channel of the base
inner frame.
66
6
7
AWP Super Series • IWP Super Series
From under the base, remove the inner frame
support tube mounting fasteners. The tube is
mounted directly under the number 1 column.
Carefully lift the machine off of the inner base
frame. Do not allow the inner base frame to fall
when lifting the machine
Crushing hazard. The machine
may fall, if it is not properly
supported by the overhead
crane when removed from the
base.
September 2016
Part No. 38139

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iwp super series