Awp/Iwp Performance And Hydraulic Specifications - Genie AWP Super Series Service Manual

Hide thumbs Also See for AWP Super Series:
Table of Contents

Advertisement

Service Manual
Specifications
AWP/IWP Perform anc e and Hydr aulic Specifications
Platform function speed, maximum
AWP-15S, 20S, 25S
and 30S
Platform up
Platform down
AWP-36S
Platform up
Platform down
AWP-40S
Platform up
Platform down
IWP - All models
Platform up
Platform down
Power Source AWP Models
DC models
AC model
Air model
Power Source IWP Models
DC models
AC model
Ambient Operating Temperature
-20°F to 135°F
-29°C to 57°C
22
AC
40 seconds
30 seconds
28 seconds
28 seconds
AC
40 seconds
52 seconds
42 seconds
42 seconds
AC
65 seconds
48 seconds
38 seconds
38 seconds
AC
40 seconds
30 seconds
28 seconds
28 seconds
12V
110V or 220V
100 psi / 6.9 bar
12V
110V or 220V
AWP Super Series • IWP Super Series
Hydraulic System
DC
Hydraulic fluid
Hydraulic tank capacity -
all models
Hydraulic System Pressure
DC
All models
Hydraulic system capacity (includes tank)
IWP-20S
DC
IWP-25S
IWP-30S
AWP-15S
DC
AWP-20S
AWP-25S
AWP-30S
AWP-36S
AWP-40S
September 2016
Chevron Rando HD equivalant
3 quarts
2.8 liters
1600 psi
110 bar
3.7 quarts
3.5 liters
3.7 quarts
3.5 liters
3.7 quarts
3.5 liters
3.7 quarts
3.5 liters
3.7 quarts
3.5 liters
3.7 quarts
3.5 liters
3.7 quarts
3.5 liters
4.0 quarts
3.8 liters
3.9 quarts
3.7 liters
Part No. 38139