8.1

Setting Method

Configure the time settings in the "Built-in Ethernet port" tab of PLC parameter.
Project window
Item
SNTP Function Setting
SNTP Server IP Address
Time Zone
Execute time setting at turn
ON/reset
At Error Occurrence
*1
Execution Interval
*1
Execution Time
*1
Either of these two options must be selected.
[Parameter]
[PLC Parameter]
button
Description
Select whether to use this function or not.
Specify the IP address of the SNTP server.
Specify a time zone in which the time is to be synchronized. Japan
Standard Time "GMT+9:00" is set by default.
Select whether to execute the time setting function upon power-on or reset
of the CPU module.
Select whether to stop or continue the time setting when an error is
detected upon power-on or reset of the CPU module.
Select this when executing the time setting function at fixed time intervals.
Select this when executing the time setting function at a specified time. (in
increments of 30 minutes)
CHAPTER 8 TIME SETTING FUNCTION (SNTP CLIENT)
[Built-in Ethernet Port Setting]
8
Setting range
Used or Not used
0.0.0.1 to
223.255.255.254
(GMT-12:00 to
GMT+13:00)
Continue or Stop
1 to 1440 (min.)
00:00 to 23:30
117