3 HUMAN INTERFACES. SETTINGS & ACTUAL VALUES 3.1 ENERVISTA 650 SETUP SOFTWARE INTERFACE
a) COMMUNICATION SETTINGS
This section details the settings related to communication parameters for the different protocols available in the F650.
Table 3.7: GENERAL OVERVIEW OF COMMUNICATION SETTINGS MENU:
COMMUNICATION
SETTINGS
Serial Ports
Network (Ethernet)
ModBus Protocol
DNP3 Slave
IEC 870-5-104
SNTP (*)
PROCOME
PTP 1588
Routing
Options enabled only in On-line mode are marked as (*). Options enabled only in Off-line mode are marked as (**)
3.1.8.2 SYSTEM SETUP
This section shows the settings related to the system setup definition such as shown in the following table.
Table 3.8: GENERAL OVERVIEW OF SYSTEM SETUP MENU:
SYSTEM
SETUP
General Settings
Flex Curves
Breaker
Miscellaneous:
Miscellaneous Settings
Options enabled only in On-line mode are marked as (*). Options enabled only in Off-line mode are marked as (**)
GEK-106310AE
Baud rate and parity for COM1 and COM2 serial communication ports.
Ethernet communication parameters for ETH_1/ETH2 or ETH_E/ETH_A/
ETH_B (Depending on model) (IP Address, Netmask, Gateway IP)
NOTE: The ModBus Slave address used by Ethernet ports is the one set
for COM2.EnerVista 650 Setup software allows programming two
different Ethernet addresses, but the first IP has always to be set as the
second IP Address is an Alias.
ModBus Slave Addresses for serial and Ethernet communication and the
ModBus port number used for ModBus TCP/IP
Physical port, Slave Address for DNP, IP Addresses for Masters, TCP/
UDP Port, Unsolicited Response parameters, Analog scale factors and
deadbands, message fragment size, Binary input block.Available for
standard and IEC61850 models.
TCP Port, Common Addr of ASDU, Cyclic Meter Period and,
Synchronization Event settings.Available for standard and IEC61850
models.
Synchronization over Ethernet settings
Comm port and slave number for procome protocol. Only available for
procome models (5).
Precission Time Protocol 1588 settings. (Available on fw version 7.00 or
higher)
A default route and a maximum number of 6 static routes may be
configured. The default route is used as the last choice, if no other route
towards a given destination is found.This option is only available for
version 7.00 and higher.
This screen describes and enables the settings of the power system
where the relay will operate. Some of these settings will be used only for
metering values presentation purposes; however, some of them apply
directly to the sampling and analog-digital conversion process (rated
frequency setting). Therefore, these settings need to be adjusted so that
they fit the system settings.
Flex Curves – Programmable user curves: The relay incorporates 4
user curves called Flex Curve A, B, C and D. The points for these curves
are defined by the user in "Setpoint>System Setup>Flex Curves>Edit
Curve" menu in EnerVista 650 Setup. User defined flex curves can be
selected as an operation curve in all the time overcurrent functions in the
relay.
Breaker Configuration
Configuration of snapshot events for each switchgear (enable or disable)
This screen contains settings related with relay working mode. Out of
service setting, Local/Remote mode and Active language mode are
options listed below.
F650 Digital Bay Controller