F007
Reset
Type Reset
Program  Utility Group
This feature assists the user when performing fault analysis or by allowing a quick
system setup change when required. Performing a Type Reset results in one of the
following user-selected post-reset configurations.
Settings:
0 — None
1 — 50 Hz Setting
2 — 60 Hz Setting
3 — Reset to Factory Settings
4 — Clear Past Trips
5 — Clear Run Timer
6 — Initialize Typeform
7 — Save User Settings
8 — Restore User Settings
9 — Clear Cumulative Fan Timer
10 — Accel/Decel Time Setting 0.01 – 600.0 Seconds
11 — Accel/Decel Time Setting 0.1 – 6000.0 Seconds
Forward/Reverse Run Selection
No Path — Direct Access Only
While operating using the keypad
sets the direction of motor rotation. This setting may be changed during operation.
This setting will not override parameter
If either direction is disabled via parameter F311, the disabled direction will not
be recognized if commanded by the keypad. If both directions are disabled via
parameter F311, the direction command from the keypad will determine the
direction of the motor rotation.
Settings:
0 — Forward
1 — Reverse
2 — Forward (EOI-Switchable F/R)
3 — Reverse (EOI-Switchable F/R)
62
(F003
is set to Panel Keypad) this parameter
F311
(Forward/Reverse Disable).
Direct Access Number — F007
Parameter Type — Selection List
Factory Default — None
Changeable During Run — No
Direct Access Number — F008
Parameter Type — Selection List
Factory Default — Forward
Changeable During Run — Yes