EOI Display
Abnormal CPU2
Abnormal CPU2 Communication.
Add-On Option 1
Add-On Option 1 Error.
Add-On Option 2
Add-On Option 2 Error.
Analog in Loss
Analog Input Loss.
Analog in OV
Analog Input Terminal Over-Voltage.
ASD Overload
ASD Overload.
ASD RAM Fault
ASD RAM Fault.
ASD ROM Fault
ASD ROM Fault.
CPU Fault
CPU Fault.
Ctrl Read Err
Initial Read Error (Parameter Initialization). • Service call required.
Current Err
Current Detection Hardware Error.
Improper Input Voltage Level at Discrete
Discrete in Volts
Input Terminal.
EEPROM Write Err
EEPROM Fault (Writing Error).
Emergency Off Command Received Via
Emergency Off
Keypad or Remotely. Output Signal From
the ASD is Terminated.
Encoder Loss
Encoder Loss.
Gate Array Fault
Gate Array Fault.
Ground Fault
Ground Fault.
Input Phase
Input Phase Failure.
Low-Current
Low-Current Operation.
Main Read Err
Initial Read Error (Parameter Initialization). • Service call required.
Q9 ASD Installation and Operation Manual
Table 12. Fault Codes
Fault Description
Possible Cause
• Service call required.
• Service call required.
• Service call required.
• V/I input terminal configured for operation but the
voltage/current input is either missing or low.
• Over-current at P24.
• Mis-wire at the ASD input terminals.
• Acceleration time is too short.
• DC Injection current is too high.
• V/f setting needs to be adjusted.
• Motor running during restart.
• ASD/motor improperly matched to the application.
• Service call required.
• Service call required.
• Service call required.
• Improper low-current detection level setting.
• Motor (phase) is disconnected.
• Discrete input terminal configured for operation
and the input activation voltage level is out of
specification.
• Service call required.
• Stop-Reset pressed twice at the EOI.
• E-Off command received remotely.
• Select stopped method at F603.
• Encoder signal not received.
• Defective gate array or gate array malfunction.
• Service call required.
• Mis-wired ground.
• Loose ground connection.
• Mis-wired input phase.
• Loose input phase connection.
• Improper low-current detection level setting.
201