EOI Remote Mounting

The Q9ASD may be controlled from a remotely-mounted EOI. For safety and application-specific
reasons, some ASD installations will warrant that the operator not be in the vicinity during operation or
that the EOI not be attached to the ASD housing. The EOI may be mounted either with or without the
optional Remote Mounting Kit (P/N ASD-MTG-KITQ9) which allows for remote EOI placement and
easier cable routing.
The EOI can operate up to 9 feet away from the ASD. An EOI extender cable is required for remote
mounting and is included with Remote Mounting Kit or can be ordered through your Toshiba Sales
Representative.
Remote Mounting Hardware
Remote Mounting Kit (Optional) — P/N ASD-MTG-KITQ9
LCD Cable, 9 ft. — P/N 76268
Remote Mounting Installation Precautions
Install the unit securely in a well ventilated area that is out of direct sunlight. The ambient temperature
rating for the display module is 14° to 104° F (-10° to 40° C).
Select a mounting location that is easily accessible by the use.
Avoid installation in areas where vibration, heat, humidity, dust, metal particles, or high levels or
electrical noise (EMI) are present.
Do not install the unit where it may be exposed to flammable chemicals or gases, water, solvents, or
other fluids.
Turn on the power only after securing the front cover of the ASD.
Remote Mounting Using the Mounting Kit
Note:
See
1.
At the EOI mounting location, mark the 4.60" by 4.50" hole and the four 11/32" screw holes.
2.
Cut the 4.60" by 4.50" rectangular mounting hole.
3.
Drill the four 11/32" screw holes for the Bezel Plate mount.
4.
Attach and secure the Bezel Plate to the front side of the mounting location using the four 10-32 hex
nuts, #10 split lock washers, and the #10 flat washers.
5.
Remove the Front Panel Assembly of the ASD — using a flathead screwdriver, release the upper
retaining tabs of the EOI panel then pivot the EOI assembly away from the ASD and lift (see
23).
6.
Remove the Display Module from the Front Panel Assembly of step 5 — discard the assembly.
7.
Attach and secure the Display Module to the front side of the Bezel Plate using the four 6-32 x
5/16" pan head screws, and the #6 split lock washers.
When installing the Display Module into the Bezel Plate ensure that the left side of the display is
inserted first with the top and bottom catches securely in place (adjacent to the Phillips screws at
underside of display). This ensures the proper alignment and electrical connection of the CNX
connector of the Display Module PCB. Then gently hold the display in place while securing the
Phillips mounting screw.