Toshiba Q9 Installation And Operation Manual page 186

Asd
Table of Contents

Advertisement

F944
Input Function Command 2
Program  My Function Unit 5
This parameter is used to assign a user-selected logical operator to two user-
selected Input Function Target variables, enable a counter/timer function, or
perform a hold/reset function.
Table 9 on pg. 194
lists the available selections. Their use and selection
requirements are described in an example at F977.
Input Function Target 3
Program  My Function Unit 5
This parameter plays a role in the setup of the My Function feature by selecting
the functionality of the programmable Input Function Target 3 terminal.
This setting assigns the function of the programmable Input Function Target 3
terminal to any of the user-selectable functions listed in
7 on pg.
190, or
Table 8 on pg.
See
F977
for more information on this parameter.
Output Function Assigned
Program  My Function Unit 5
This parameter plays a role in the setup of the My Function feature by selecting
the functionality of the Output Function Assigned terminal.
This setting assigns the function of the programmable Output Function Assigned
data location to 1 of the functions listed in the Input Setting field of
pg.
190.
Settings:
0 – 3099
See the My Function Instruction Manual (P/N E6581335) and
information on this parameter.
Input Function Target 1
Program  My Function Unit 6
This parameter plays a role in the setup of the My Function feature by selecting
the functionality of the programmable Input Function Target 1 terminal.
This setting assigns the function of the programmable Input Function Target 1
terminal to any of the user-selectable functions listed in
7 on pg.
190, or
Table 8 on pg.
See
F977
for more information on this parameter.
Input Function Command 1
Program  My Function Unit 6
This parameter is used to assign a user-selected logical operator to two user-
selected Input Function Target variables, enable a counter/timer function, or
perform a hold/reset function.
Table 9 on pg. 194
lists the available selections. Their use and selection
requirements are described in an example at F977.
176
Table 5 on pg.
192.
Table 5 on pg.
192.
Direct Access Number — F944
Parameter Type — Selection List
Factory Default — 0 (NOP)
Direct Access Number — F945
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes
188,
Table
Direct Access Number — F946
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes
Table 7 on
F977
for more
Direct Access Number — F947
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes
188,
Table
Direct Access Number — F948
Parameter Type — Selection List
Factory Default — 0 (NOP)
Q9 ASD Installation and Operation Manual
F948

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents