Spectrum scope screen (Continue)
D Scope set screen
The Scope Set screen is used to configure the scope
screen parameters, such as the waveform color.
1. Open the SPECTRUM SCOPE screen.
» SCOPE
MENU
2. Touch [EXPD/SET] for 1 second.
• Opens the SCOPE SET window.
3. Select the desired item.
4. Select the option or set the level.
L See to the right for details of the setting items and
their options.
5. To exit the SPECTRUM SCOPE screen, push
several times.
TIP: How to reset to the default setting
Touching the item or its option for 1 second displays
the Quick menu, and then touch "Default" to reset to
the default setting.
Max Hold
Select the peak level holding function.
• OFF:
Turns OFF the peak level holding
function.
• 10s Hold: Holds the peak spectrum for 10 seconds.
• ON:
Turns ON the peak spectrum.
CENTER Type Display
Select the center frequency of the SPECTRUM
SCOPE screen. (Only in the Center mode)
• Filter Center: Displays the selected filter's center
frequency in the center of the
SPECTRUM SCOPE screen.
• Carrier Point Center:
Displays the carrier point frequency
of the selected operating mode in the
center of the SPECTRUM SCOPE
screen.
• Carrier Point Center (Abs. Freq.*):
In addition to the carrier point center
setting above, the actual frequency is
displayed at the bottom of the scope.
Marker Position (Fix Type)
Select the marker position on the SPECTRUM
SCOPE screen. (Only in the Fixed mode)
• Filter Center: Displays the Marker on the selected
filter's center frequency.
• Carrier Point: Displays the Marker on the carrier
point frequency of the selected
operating mode.
VBW
Select the Video Band Width (VBW).
• Narrow:
Sets the VBW to narrow.
• Wide:
Sets the VBW to wide.
L When "Wide" is selected, the line drawn on the receive
spectrum becomes wide. However, the small edge cannot
be drawn.
Averaging
Set the FFT scope waveform averaging function to
between 2 and 4, or OFF.
• OFF:
The FFT scope screen refreshes at each
sweep time. This setting displays the
critical spectrum view.
• 2, 3, 4:
The FFT scope screen averages 2
to 4 sweeps to smoothly display the
spectrum.
4-5
SCOPE OPERATION
(Default: 10s Hold)
(Default: Filter Center)
*Abs. Freq. : Absolute Frequency
(Default: Carrier Point)
(Default: Narrow)
(Default: OFF)