Time Set; Sd Card; Others - Icom IC-R8600 Instruction Manual

Communications receiver
Hide thumbs Also See for IC-R8600:
Table of Contents

Advertisement

Time Set

» SET > Time Set
MENU
Dmte
Date/Time >
Sets the date* (Year/Month/Day).
• Settable range: 2000/01/01 ~ 2099/12/31
LThe day of the week is automatically set.
L If the NTP Function is ON and receiver is connected to
Internet, these items are automatically set.
Time
Date/Time >
Sets the current time.
• Settable range: 0:00 ~ 23:59
LThe time is displayed in the 24 hour format.
L If the NTP Function is ON and receiver is connected to
Internet, these items are automatically set.
Date/Time >
<<NTP TIME SYNC>>
Touch to synchronize the internal clock to the NTP server.
• Automatically obtains the current time from the NTP server.
NTP Function
Date/Time >
Automatically obtains the current time from the NTP server.
• OFF: Turn OFF the function.
• ON:
Use the function. (An internet access is necessary.)
NTP Server Address (Default: time.nist.gov)
Date/Time >
Sets the NTP server address.
LDo not change this setting, unless it is necessary.
LRefer to page 1-7 for the character entering.
UTC Onnset
Sets the UTC offset time.
• Range: –14:00 to +14:00 (in 5 minute steps)
SD Cmrd
» SET > Time Set
MENU
Lomd Setting
Selects the saved data file to load.
L See "Using An SD Card" in Section 7 for data load details.
Smve Setting
Saves the setting data onto an SD card.
L See "Using An SD Card" in Section 7 for data write details.
SD Cmrd Inno
Displays the SD card capacity and the time remaining
for recording.
Screen Cmpture View
Displays the selected screen capture.
L See "Screen Capture function" (p. 5-11) for details.
(Default: 2000/01/01)
(Default: 0:00)
(Default: ON)
(Default: + 0:00)
11-10
SD Card (Continued)
Firmwmre Updmte
Enters the Firmware Update mode.
L See "Updating the firmware" (p. 13-1) for details.
Formmt
Formats the SD card.
L See "Formatting an SD card" (p. 7-2) for details.
Unmount
Unmounts the SD card.
NOTE:
Before you remove a card when the receiver is ON,
be sure to electrically unmount it (p. 7-1). Otherwise
the data may be corrupted or deleted.

Others

» SET > Other
MENU
Version
Information >
Displays the firmware version.
Clone Mode
Clone >
Touch to enter the cloning mode.
L The cloning mode is cancelled on restart.
Touch Screen Cmlibrmtion
Touch to adjust the touch screen.
L Touch the white dots that sequentially appears on the screen.
<<BER Memsurement Stmrt/Stop>>
Touch to enter or quit the BER Measurement mode.
• "BER" is displayed while in the measurement mode.
• Push
to select the testing signal type (Clock/Data or
UART) and measurement mode (General or P25 specific).
Pmrtiml Reset
Reset >
Touch to return all the settings to their factory defaults
except the memory channels.
L See "Resetting" (p. 12-2) for details.
All Reset
Reset >
Touch to return all the settings to their factory defaults,
and clears all the memory channels.
L See "Resetting" (p. 12-2) for details.
11
SET MODE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

Advertisement

Table of Contents
loading

Table of Contents