errdisable recovery
Examples
This example shows how to enable the recovery timer for the BPDU guard error-disabled cause:
Switch(config)# errdisable recovery cause bpduguard
This example shows how to set the timer to 500 seconds:
Switch(config)# errdisable recovery interval 500
You can verify your settings by entering the show errdisable recovery privileged EXEC command.
Related Commands
Command
show errdisable recovery
show interfaces
err-disabled
clear errdisable interface
Catalyst 3750 Switch Command Reference
2-188
Description
Displays error-disabled recovery timer information.
status
Displays interface status or a list of interfaces in error-disabled
state.
Clears the error-disabled state from a port or VLAN that was error
disabled by the per-VLAN error disable feature.