Main Functions; Gpio (Digital Input/Output Settings); Valid Input/Output Combinations - IAI GO-2400M-USB User Manual

2.35m digital progressive scan monochrome and color camera
Table of Contents

Advertisement

Main Functions

GPIO (Digital Input/Output Settings)

The camera is equipped with GPIO (general-purpose input/output) functions for generating and using
combinations of triggers and other necessary signals within the camera and of signals output from the
camera to the system such as those used for lighting equipment control.

Valid Input/Output Combinations

The following signals can be used as sources for each output destination (Trigger Selector, Line
Selector, Pulse Generator Selector).
You can also connect two different sources to NAND paths in the GPIO and reuse the signal generated
there as a source for a different selector.
The combinations of source signals and output destinations are indicated in the following.
(Cross point
switch output)
Source signal
(Cross point
switch input)
LOW
HIGH
User Output 0
User Output 1
Software
Pulse Generator 0
NAND 0 Out
NAND 1 Out
Line5-Optical In 1
FVAL
LVAL
Acquisition Trigger Wait
Frame Trigger Wait
Frame Active
Exposure Active
: Indicates default values for each selector. "Factory default values" (page 16) shows the
default values for [Frame Start].
Selector
Output destination
Trigger Selector
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
Trigger Source
— 23 —
Line Selector
×
×
×
×
×
×
×
×
×
×
×
Line Source
Use
GO-2400M-USB / GO-2400C-USB