3D Systems ProX DMP 100 User Manual page 48

3d production printer
Hide thumbs Also See for ProX DMP 100:
Table of Contents

Advertisement

4
Information area
OXYGEN
Gas: status of the gas valve indicator: if green, the valve is opened,
Gas
(mode of the gas supplied): REGUL (regulation around an oxygen target value), DIRECT (continuous injection of
gas at a constant rate), OFF (no gas injection),
Value: current oxygen level value in PPM (particles per million) in the manufacturing chamber,
Setpoint: oxygen level target value,
Pressure: current pressure value on the manufacturing chamber .
TEMPERATURE
Oven: status of the oven: if green/white, the oven is operating/not operating,
Value: current temperature value on the manufacturing chamber,
Setpoint: temperature target value .
LENS CLEANER
Turbine: state of the lens cleaner blower (turbine) . If green/white, the blower is operating/not operating,
Setpoint: setpoint of the blower operating, in %,
Differential pressure
PART
Available
powder: the height of the powder available in the feeding piston in mm,
Zero
sintering: the zero position of the sintering piston in mm (corresponding to the last zero sintering research
cycle),
Part
height: the height of the sintered part in mm .
LASER/OPTIC
Defocus: defocusing value in mm,
Laser
power: current Laser power, in % .
3D SYSTEMS, INC.
: [Outlet Pressure – Inlet Pressure] of the process filter.
44
PN:80-D48 REV A