Test Operation Mode In Mr Configurator2 - Mitsubishi Electric MR-J4W2 Instruction Manual

Servo amplifers melservo-j4
Table of Contents

Advertisement

4. STARTUP

4.5.1 Test operation mode in MR Configurator2

(1) Test operation mode
(a) Jog operation
Jog operation can be performed without using the servo system controller. Use this operation with
the forced stop reset. This operation may be used independently of whether the servo is on or off
and whether the servo system controller is connected or not.
Exercise control on the jog operation screen of MR Configurator2.
1) Operation pattern
2) Operation method
When the check box of "Rotation only while the CCW or CW button is being pushed." is
checked.
When the check box of "Rotation only while the CCW or CW button is being pushed." is not
checked.
POINT
All axes will be in the test operation mode for the multi-axis servo amplifier.
Although only one axis is active in the mode.
When the test operation mode is selected with the test operation select switch
(SW2-1), the SSCNET III/H communication for the servo amplifier in the test
operation mode and the following servo amplifiers is blocked.
Item
Speed [r/min]
Acceleration/deceleration
time constant [ms]
Operation
Forward rotation start
Reverse rotation start
Stop
Forced stop
Operation
Forward rotation start
Reverse rotation start
Stop
Forced stop
Default value
200
1000
Keep pressing the "Forward" button.
Keep pressing the "Reverse" button.
Release the "Forward" or "Reverse" button.
Click the "Forced stop" button.
Click the "Forward" button.
Click the "Reverse" button.
Click the "Stop" button.
Click the "Forced stop" button.
4 - 15
Setting range
0 to max. speed
0 to 50000
Screen control
Screen control

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j4w3Mr-j4w2-0303b6

Table of Contents