5. PARAMETERS
5.1 Parameter list
POINT
The parameter whose symbol is preceded by * is enabled with the following
conditions:
*: After setting the parameter, cycle the power or reset the controller.
**: After setting the parameter, cycle the power.
How to set parameters
Each: Set parameters for each axis of A, B, and C.
Common: Set parameters for common axis of A, B, and C. Be sure to set the
same value to all axes.
The same values are set as default for all axes.
Abbreviations of operation modes indicate the followings.
Standard: Standard (semi closed loop system) use of the rotary servo motor
Full.: Fully closed loop system use of the rotary servo motor
Lin.: Linear servo motor use.
D.D.: Direct drive (D.D.) motor use.
For MR-J4W2-0306B6 servo amplifiers, the operation mode is available only in
standard (semi closed loop system).
Setting an out of range value to each parameter will trigger [AL. 37 Parameter
error].