5. PARAMETERS

5.2.4 I/O setting parameters ([Pr. PD_ _ ])

No.
Symbol
PD02
*DIA2
Input signal automatic on selection 2
Setting digit
HEX.
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
Convert the setting value into hexadecimal as follows.
0 0 0
When you perform a magnetic pole detection without using FLS (Upper stroke limit)
and RLS (Lower stroke limit), setting [Pr. PL08 Linear servo motor/DD motor function
selection 3] to "_ 1 _ _" allows you to disable FLS and RLS.
Name and function
Explanation
BIN.
_ _ _ x
FLS (Upper stroke limit) selection
0: Disabled
1: Enabled
_ _ x _
RLS (Lower stroke limit) selection
0: Disabled
1: Enabled
_ x _ _
For manufacturer setting
x _ _ _
For manufacturer setting
FLS (Upper stroke limit) selection
RLS (Lower stroke limit) selection
BIN 0: Disabled (Use for an external input signal.)
BIN 1: Automatic on
5 - 43
Initial value
Signal name
BIN HEX
Initial
Setting
value
range
[unit]
Refer to Name
and function
Initial
column.
value
0h
0h
0h
0h
0
0
0
0
0
Each/
Common
Each