Mitsubishi Electric MR-J4W2 Instruction Manual page 130

Servo amplifers melservo-j4
Table of Contents

Advertisement

5. PARAMETERS
No.
Symbol
PB58
VRF23B Vibration suppression control 2 - Vibration frequency damping after gain switching
Set a damping of the vibration frequency for vibration suppression control 2 when the
gain switching is enabled.
To enable this, select "3 inertia mode (_ _ _ 1)" of "Vibration suppression mode
selection" in [Pr. PA24].
This parameter will be enabled only when the following conditions are fulfilled.
"Gain adjustment mode selection" in [Pr. PA08] is "Manual mode (_ _ _ 3)".
"Vibration suppression control 2 tuning mode selection" in [Pr. PB02] is "Manual
setting (_ _ 2 _)".
"Gain switching selection" in [Pr. PB26] is "Control command from controller is
enabled (_ _ _ 1)".
Switching during driving may cause a shock. Be sure to switch them after the servo
motor or linear servo motor stops.
PB59
VRF24B Vibration suppression control 2 - Resonance frequency damping after gain switching
Set a damping of the resonance frequency for vibration suppression control 2 when
the gain switching is enabled.
To enable this, select "3 inertia mode (_ _ _ 1)" of "Vibration suppression mode
selection" in [Pr. PA24].
This parameter will be enabled only when the following conditions are fulfilled.
"Gain adjustment mode selection" in [Pr. PA08] is "Manual mode (_ _ _ 3)".
"Vibration suppression control 2 tuning mode selection" in [Pr. PB02] is "Manual
setting (_ _ 2 _)".
"Gain switching selection" in [Pr. PB26] is "Control command from controller is
enabled (_ _ _ 1)".
Switching during driving may cause a shock. Be sure to switch them after the servo
motor or linear servo motor stops.
PB60
PG1B
Model loop gain after gain switching
Set the model loop gain when the gain switching is enabled.
When you set a value less than 1.0 rad/s, the value will be the same as [Pr. PB07].
This parameter will be enabled only when the following conditions are fulfilled.
"Gain adjustment mode selection" in [Pr. PA08] is "Manual mode (_ _ _ 3)".
"Gain switching selection" in [Pr. PB26] is "Control command from controller is
enabled (_ _ _ 1)".
Switching during driving may cause a shock. Be sure to switch them after the servo
motor or linear servo motor stops.
Name and function
5 - 35
Initial
Setting
Each/
value
range
Common
[unit]
0.00
0.00 to
Each
0.30
0.00
0.00 to
Each
0.30
0.0
0.0 to
Each
[rad/s]
2000.0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j4w3Mr-j4w2-0303b6

Table of Contents