Mitsubishi Electric MR-J4W2 Instruction Manual page 117

Servo amplifers melservo-j4
Table of Contents

Advertisement

5. PARAMETERS
No.
Symbol
PA24
AOP4
Function selection A-4
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
PA25
OTHOV
One-touch tuning - Overshoot permissible level
Set a permissible value of overshoot amount for one-touch tuning as a percentage of
the in-position range.
However, setting "0" will be 50%.
Name and function
Explanation
Vibration suppression mode selection
0: Standard mode
1: 3 inertia mode
2: Low response mode
When two low resonance frequencies are generated, select
"3 inertia mode (_ _ _ 1)". When the load to motor inertia
ratio exceeds the recommended load to motor inertia ratio
select "Low response mode (_ _ _ 2)".
When you select the standard mode or low response mode,
"Vibration suppression control 2" is not available.
When you select the 3 inertia mode, the feed forward gain
is not available.
Before changing the control mode with the controller during
the 3 inertia mode or low response mode, stop the motor.
For manufacturer setting
5 - 22
Initial
Setting
value
range
[unit]
Refer to Name
and function
Initial
column.
value
0h
0h
0h
0h
0
0
[%]
to
100
Each/
Common
Each
Each

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j4w3Mr-j4w2-0303b6

Table of Contents