Mechanical Data; Pneumatic Data; Position Measuring System Data; Electrical Data - Burkert 8681 Quick Start Manual

Control head for decentralized automation of hygienic process valves
Hide thumbs Also See for 8681:
Table of Contents

Advertisement

Available languages

Available languages

6.4.
Mechanical Data
Dimensions:
see data sheet
Housing material:
outside:
inside:
Sealing material:
outside:
inside:
6.5.
Pneumatic Data
Control medium:
air, neutral gases,
Quality classes in accordance with
ISO 8573-1
(5 µm filter recommended)
Dust content:
max. particle size 40 µm,
(quality class 7)
max. particle density 10 mg/m
Water content:
max. pressure dew point -20 °C or
(quality class 3)
min. 10 °C below the lowest operating
temperature
Oil content:
max. 25 mg/m
(quality class X)
Temperature range
of compressed air:
-10 to +50 °C
Pressure range:
2.5 to 8 bar
10
PA, PC, PPO, VA
ABS, PA, PMMA
CR, EPDM
EPDM, FKM, NBR
3
3
english
Type 8681
TechnicalData
Air rate of solenoid
valve:
110 I
(110 I
200 I
(Q
Nn
pressure drop from 7 to 6 bar absolute
at +20 °C)
Connections:
intake and exhaust air connection G1/4
Working connections
6.6.
Position Measuring System Data
Stroke range:
0 ... 80 mm (measuring range)
≤ 0.1 mm
Resolution:
Total fault:
± 0.5 mm - when using a target as
mentioned in the manual
6.7.
Electrical Data
see chapter
"8. 24 V DC - Design",
"9. AS-i - Design",
"10. DeviceNet- Design" and
"11. 120 V AC - Design".
/min (for de-/aeration, ventilation)
N
/min - supplied state
N
/min - maximum typical flow-rate)
N
value according to definition for
G1/8