Technical Data; Standards And Directives; Operating Conditions; Mechanical Data - Burkert 6014 Operating Instructions Manual

3/2-way solenoid valve
Table of Contents

Advertisement

Available languages

Available languages

5

TECHNICAL DATA

5.1

Standards and directives

The device complies with the relevant EU harmonisation legislation.
In addition, the device also complies with the requirements of the
laws of the United Kingdom.
The harmonised standards that have been applied for the con-
formity assessment procedure are listed in the current version of
the EU Declaration of Conformity/UK Declaration of Conformity.

5.2 Operating conditions

WARNING!
Risk of injury from discharge of medium and pressure.
▶ If the device is used outdoors, do not expose it unprotected to
the weather conditions.
▶ Avoid heat sources which may cause the allowable tempera-
ture range to be exceeded.
Ambient temperature
-10 – +55 °C
Degree of protection
IP65 in accordance with EN 60529 with
cable plug
6

5.3 Mechanical data

Dimensions
See data sheet
Port connection
Type 6014
Type 6014P
Hollow screw G1/8, G1/4
Materials
Body
Type 6014
Type 6014P
Hollow screw
Type 6014P
Base plate
Type 6014P
Sealing
Type 6014
Type 6014P
G1/8, G1/4, flange
G1/8, G1/4
brass, stainless steel 1.4305,
polyamide (PA, flange)
brass, polyamide (PA)
brass,
stainless steel 1.4301/304
aluminium anodized or IXEF
FKM, EPDM on request
FKM

Advertisement

Table of Contents
loading

Table of Contents