Electrical Data; Electrical Installation (Dvn) - Burkert 8681 Quick Start Manual

Control head for decentralized automation of hygienic process valves
Hide thumbs Also See for 8681:
Table of Contents

Advertisement

Available languages

Available languages

DeviceNet-Design
10.4. Electrical Data
Electrical power supply:
Max. power consumption: 200 mA at 24 V DC
Input / proximity switches (external initiator: S4 in):
Power supply:
Current carrying capacity
sensor power supply:
Short-circuit protection
Design:
Input current 1 signal:
Input voltage 1 signal:
Input current 0 signal:
Input voltage 0 signal:
Inputs (from master perspective) / binary or analog feedback
signals:
The recovery of the 3 valve positions reported back binarily or of the
analog position signalis described in the manual, chapter "Position
Mesuring System".
Outputs (from master perspective) / solenoid valves:
max. switching capacity 1.0 W (per solenoid valve)
typ. continuous output
Type 8681
11 to 25 V DC (according to
specification)
via DeviceNet power supply - 10 %
max. 30 mA
DC 2- and 3-conductor,
NO contact, PNP output
I
> 6.5 mA, limited internally
Sensor
to 10 mA
U
> 10 V
Sensor
I
< 4 mA
Sensor
U
< 5 V
sensor
0.6 W (per solenoid valve)
Output reduction
pull-in current
Holding current
Operating mode
Central display of the switching states:
Power consumption from
DeviceNet at 24 V DC
10.5. Electrical Installation (DVN)
DANGER!
Danger of explosion in explosive atmosphere
(only in the event of a fault as it is zone 2)!
• Opening the hood or the housing in an explosive atmosphere is
only allowed in a not energized state!
WARNING!
Risk of injury due to electrical shock!
• Before reaching into the system (except for the Teach-In proce-
dure in a non-explosive atmosphere) switch off the power supply
and secure it to prevent restarting! Observe applicable accident
prevention and safety regulations for electrical equipment!
Risk of injury from improper installation!
• Installation may be carried out by authorized technicians only and
with the appropriate tools!
english
integrated via DeviceNet interface
electronics
120 mA typ. / 200 ms (3 valves)
100 mA typ. at 24 V DC (3 valves)
Long-term operation (100 % operation)
42 mA with 24 V DC power supply
per illuminated display shown
19

Advertisement

Table of Contents
loading

Table of Contents