7.4.3
Media
Control medium
neutral gases, air
Flow medium
water, alcohol, fuel, hydraulic liquids,
saline solutions, lye, organic solvents
7.5
Control functions
Control function A
Normally closed by spring action
Control function B
Normally open by spring action
Control function I
Actuating function via reciprocal
pressurization
7.6
Mechanical data
Materials
Valve body
Stainless steel 316L
Actuator
PA
Seals materials
PTFE
(NBR, FKM and EPDM on request)
Packing gland
PTFE (carbon-filled)
Type 2012
Installation
8
INSTALLATION
8.1
Safety instructions
DANGER!
Risk of injury from high pressure.
▶ Before loosening the lines and valves, turn off the pressure and
vent the lines.
WARNING!
Risk of injury from improper installation.
▶ Installation may be carried out by authorized technicians only and
with the appropriate tools.
Risk of injury from unintentional activation of the system and
an uncontrolled restart.
▶ Secure system from unintentional activation.
▶ Following installation, ensure a controlled restart.
For control function I – Danger if pilot pressure fails.
For control function I control and resetting occur pneumatically. If
the pressure fails, no defined position is reached.
▶ To ensure a controlled restart, first pressurize the device with pilot
pressure, then switch on the medium.
Risk of injury from moving parts in the device.
▶ Do not reach into openings.
english
11