Control Functions; Mechanical Data; Installation; Safety Instructions - Burkert 2012 Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

7.4.3
Media
Control medium
neutral gases, air
Flow medium
water, alcohol, fuel, hydraulic liquids,
saline solutions, lye, organic solvents
7.5

Control functions

Control function A
Normally closed by spring action
Control function B
Normally open by spring action
Control function I
Actuating function via reciprocal
pressurization
7.6

Mechanical data

Materials
Valve body
Stainless steel 316L
Actuator
PA
Seals materials
PTFE
(NBR, FKM and EPDM on request)
Packing gland
PTFE (carbon-filled)
Type 2012

Installation

8
INSTALLATION
8.1

Safety instructions

DANGER!
Risk of injury from high pressure.
▶ Before loosening the lines and valves, turn off the pressure and
vent the lines.
WARNING!
Risk of injury from improper installation.
▶ Installation may be carried out by authorized technicians only and
with the appropriate tools.
Risk of injury from unintentional activation of the system and
an uncontrolled restart.
▶ Secure system from unintentional activation.
▶ Following installation, ensure a controlled restart.
For control function I – Danger if pilot pressure fails.
For control function I control and resetting occur pneumatically. If
the pressure fails, no defined position is reached.
▶ To ensure a controlled restart, first pressurize the device with pilot
pressure, then switch on the medium.
Risk of injury from moving parts in the device.
▶ Do not reach into openings.