System Reset - Extron electronics FOX T UWP 302 User Manual

Two input fiber optic transmitter - decora wallplate
Hide thumbs Also See for FOX T UWP 302:
Table of Contents

Advertisement

System Reset

Use the Reset button beneath the faceplate to return the device to default settings or to
restore factory-shipped firmware (see to the Reset Mode Summary table below for more
details). If necessary, remove the faceplate.
Mode
Mode Activation
1
Hold the Reset button down
while applying power to the
device.
NOTE: After a mode 1
reset, update the device
with the latest firmware
version. DO NOT operate
the firmware version that
results from this mode
reset.
5
Hold the Reset button down
for about 9 seconds or until
the Power LED blinks three
times. Then press the Reset
button momentarily (for
<1 second) within 1 second.
NOTE: The reset
procedure is aborted if
the second momentary
press does not occur
within one second.
Reset Mode Summary
Result
The device reverts to the factory
default firmware.
All user files and settings (audio
adjustments, audio input selection,
input selection, auto-switch mode,
picture adjustments, and input
video format) are maintained.
Mode 5 performs a complete
reset to factory defaults except for
firmware.
Reset all user modifiable
configurations to default values
including real-time adjustments.
The Power LED blinks 4 times in
quick succession during the reset.
FOX T UWP 302 Wallplate Transmitter • Installation and Operation
Purpose/Notes
Use mode 1 to revert
to factory firmware for
a single power cycle if
an incompatibility issue
arises.
Use mode 5 to start
over with configuration
or uploading.
NOTE: This is
equivalent to SIS
command
.
ZXXX
14

Advertisement

Table of Contents
loading