Mounting and Making Connections

Mounting

Before mounting an electrical UL Listed junction box, consider the mounting location and
prepare the surface as necessary.
Mounting
Screws
(6 Plcs)
Figure 6.
1.
2.
3.
Flush with
Wall Surface
2
3
Mounting the FOX T UWP 302 Into a Junction Box
Mount the junction box in the wall or floor, following the directions provided with the
box.
Run the cables through the junction box (see figure 6,
ATTENTION:
To prevent short circuits, the outer foil shield can be cut back to the point
where the cable exits the cable clamp. Both braided and foil shields should be
connected to an equipment ground at the other end of the cable.
Ain d'éviter les court circuits, le blindage en aluminium extérieur peut être
réduit jusqu'à ce que le câble sorte de la cosse de câble. Le blindage tressé et
le blindage en aluminium devraient être connectés à la masse d'un équipement
à l'autre bout du câble.
Secure cables with clamps or ties to provide strain relief.
TIP:
Disconnect power from all devices at the source.
FOX T UWP 302 Wallplate Transmitter • Installation and Operation
Wall Stud
Junction Box
Screws or Nails
Extron
FOX T UWP 302
Universal Wallplate
Transmitter