Operation

After all devices are connected and powered, the system is fully operation. The
FOX T UWP 302 can be configured through SIS commands (see
Control
Program

Initial Power Up

Upon initial power up, all the front panel LEDs blink simultaneously. They blink once to
indicate the device is a multimode device or twice to indicate the device is a singlemode
device. Afterwards, the LEDs return to their normal signal presence indication.
If a different SFP module or no SFP module is connected, the LEDs first blink once or twice
to identify the device and then blink continuously.
This product is intended to be supplied by a UL Listed Power Unit marked
"Class 2" or "LPS," rated 12 VDC, 1.0 A minimum. Always use a power supply
supplied by or speciied by Extron. Use of an unauthorized power supply voids all
regulatory compliance certiication and may cause damage to the supply and the
unit.
Ce produit est destiné à une utilisation avec une source d'alimentation listée UL
avec l'appellation « Classe 2 » ou « LPS » et normée 12 Vcc, 1,0 A minimum.
Utilisez toujours une source d'alimentation fournie par Extron. L'utilisation d'une
source d'alimentation non autorisée annule toute conformité réglementaire et peut
endommager la source d'alimentation ainsi que l'unité.
Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling
spaces or in wall cavities. The installation must always be in accordance with the
applicable provisions of National Electrical Code ANSI/NFPA 70, article 725 and
the Canadian Electrical Code part 1, section 16. The power supply shall not be
permanently ixed to a building structure or similar structure.
Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour
une utilisation dans les espaces d'aération ou dans les cavités murales. Cette
installation doit toujours être en accord avec les mesures qui s'applique au National
Electrical Code ANSI/NFPA 70, article 725, et au Canadian Electrical Code,
partie 1, section 16. La source d'alimentation ne devra pas être ixée de façon
permanente à une structure de bâtiment ou à une structure similaire.
Power supply voltage polarity is critical. Incorrect voltage polarity can damage the
power supply and the unit. The ridges on the side of the cord identify the power
cord negative lead.
La polarité de la source d'alimentation est primordiale. Une polarité incorrecte
pourrait endommager la source d'alimentation et l'unité. Les stries sur le côté du
cordon permettent de repérer le pôle négatif du cordon d'alimentation.
Do not tin the stripped power supply leads. Tinned wires are not as secure in the
captive screw connectors and could be pulled out.
on page 15) or the FOX Extenders control program (see
on page 23).
FOX T UWP 302 Wallplate Transmitter • Installation and Operation