16.7.1 Product specifications

The generic specifications are identical to the main unit specifications.
For external wiring, refer to the following chapters.
1. Power supply specifications
Item
Product type
Rated voltage
2. Weight and Other specifications (External dimensions are described later.)
Item
MASS (Weight)
Other
3. Input specifications
Item
Input points
Connection type
Input form
Input signal voltage
Input signal current
Input impedance
Input ON current
ON input
sensitivity current
Input OFF current
Input response time
Input signal form
Input circuit insulation
Indication of input operation
Input circuit diagram
→ Refer to Section 4.1 for generic specifications.
24V DC (supplied from main unit and input/output powered extension unit)
The extension cable is already connected to the extension block.
Accessories: Label for indication of input/output number
The DIN46277 rail (width: 35 mm (1.38")) or direct installation.
Vertical terminal block (M3 screws)
6.2mA/110V AC 60Hz 4.7mA/100V AC 50Hz
LED on panel lights when input.
Photocoupler
Input impedance
Photocoupler
Input impedance
16 Input/Output Extension Blocks
16.7 FX2N-8EX-UA1/UL (100V AC Input)
→ Refer to Chapter 10 for input wiring.
FX
-8EX-UA1/UL
2N
FX
2N
extension block
FX
-8EX-UA1/UL
2N
0.2kg (0.44lbs)
FX
2N
-8EX-UA1/UL
8 points
AC input
100 to 120V AC
Approx. 21k /50Hz
Approx. 18k /60Hz
3.8mA/80V AC or more
1.7mA/30V AC or more
Approx. 25 to 30ms
Voltage contact
Photo-coupler insulation
100 to 120V AC
COM
Fuse
X*0
X*7
11
12
13
14
15
16
17
18
19
20
229