19.11 Keyword

Keywords registered at the PLC can be canceled from the "Keyword" menu.
When canceled, all operations are enabled.
Registering or changing keywords is not possible at the display module.
The programming tool must be used in advance to register new keywords.

19.11.1 Keyword types and levels

Keywords can be entered in 2 ways (8-digit or 16-digit
• For a [keyword (8-digit)] + [2nd keyword (8-digit)] = 16-digit input:
Processing is possible only with a peripheral device version compatible with the FX
• For an keyword (8-digit) input only:
Processing is possible even with a peripheral device version that is not compatible with the FX
Number
Of
Registration Method
Digits
By selecting the keyword
16-digit
registration level at the GX
*1
Developer's setting screen.
By entering the level at the
8-digit
first character when entering
the keyword
*1.
Customer keyword/Permanent PLC lock included

19.11.2 Level-specific restrictions screen list

: Function enabled
: Timer and counter setting values cannot be changed.
: Only monitor function is usable (test function is not available)
-: Function disabled
Function name
Top screen (time display)
Top screen (Specified device monitor)
Monitor/Test
ErrorCheck
Menu display language setting
Contrast adjustment
Time
Keyword (cancel)
Memory cassette transfer
Display screen protect function
*1.
Customer keyword/Permanent PLC lock included
288
Peripheral Device
FX
3G
Compatible
None
Display
Setting
-
*1
), depending on the peripheral device in question.
Keyword
Not FX
3G
Registration Level
Compatible
Reading/writing
prohibited
-
Writing prohibited
All online operations
prohibited
A
(A, 0 to 9 first char.)
B
C
Keyword: 8 digits
Label entered as the first
character at Keyword input
A
B
C
-
-
-
-
-
-
-
-
-
19 Display Module(FX3G-5DM)
PLC.
3G
Keyword Description
16-digit hexadecimal value
(A to F, 0 to 9)
[Ex]
FAB05C25DAECF293
AABCDEFF34509345
8-digit hexadecimal value beginning with
"A" or "0 to 9".
[Ex]0ABCDEF2, AABCD345
8-digit hexadecimal value beginning with
"B".
[Ex]B1234567,BABCDEF7
8-digit hexadecimal value beginning with
"C".
[Ex]C8904567,CDEF567F
Keyword: 16 digits
Selected at GX Developer setting screen
All online
Writing
operations
prohibited
prohibited
-
-
-
-
-
-
-