Download Print this page
Mitsubishi FX3G-2AD-BD Installation Manual
Mitsubishi FX3G-2AD-BD Installation Manual

Mitsubishi FX3G-2AD-BD Installation Manual

Melsec-f fx3g series
Hide thumbs Also See for FX3G-2AD-BD:

Advertisement

Quick Links

JY997D33501B
Side
B
Side
Side
A
B
JAPANESE
ENGLISH
FX
-2AD-BD
3G
INSTALLATION MANUAL
Manual Number
JY997D33501
Revision
B
Date
September 2008
This manual describes the part names, dimensions, mounting, and
specifications of the product. Before use, read this manual and the manuals of
all relevant products fully to acquire proficiency in handling and operating the
product. Make sure to learn all the product information, safety information, and
precautions.
Store this manual in a safe place so that it can be taken out and read whenever
necessary. Always forward it to the end user.
Registration:
The company and product names described in this manual are registered
trademarks or the trademarks of their respective companies.
Effective September 2008
Specifications are subject to change without notice.
©
2008 Mitsubishi Electric Corporation
Safety Precaution
(Read these precautions before use.)
This manual classifies the safety precautions into two categories:
and
.
IIndicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.
Depending on the circumstances, procedures indicated by
also cause severe injury.
It is important to follow all precautions for personal safety.
Associated Manuals
Manual name
Manual No.
Description
FX
/F X
/ FX
Describes specifications for
3 G
3 U
3 U C
JY997D16701
Series User's Manual
analog control and programming
MODEL CODE:
- Analog Control
method for FX
/FX
3G
09R619
Edition
Series PLC.
FX
3G
Series
JY997D31301
E x p l a i n s F X
S e r i e s P L C
3 G
User's Manual
MODEL CODE:
specifications for I/O, wiring,
installation, and maintenance.
- Hardware Edition
09R521
How to obtain manuals
For product manuals or documents, consult with the Mitsubishi Electric dealer
from who you purchased your product.
1. Outline
The FX
3G
-2AD-BD boards for analog input (hereinafter called 2AD-BD) is an
expansion boards to add two analog input points.
1.1 Incorporated Items
Product
Analog input expansion board FX
M3×8 tapping screws for installation: 2 pcs.
Included items
Side cover
Installation Manual (This manual)
1.2 External Dimensions, Part Names
[4]
[3]
[2]
[1]
35(1.38")
15.1
14.1
(0.6") (0.56")
[6]
[1]Terminal block mounting screws
[2]POW LED: Lit while power is properly supplied from main unit
[3]Mounting holes(2- 3.2)
[4]Connector cover
[5]Main unit connector
[6]Terminal block to connect analog input
[7]Memory casette/Display module connector
1.2.1
Terminal Layout
may
5 poles
/FX
3U
3UC
2. Installation
For installation/uninstallation details, refer to the following manuals:
→ Refer to the FX
INSTALLATION
PRECAUTIONS
3G
-2AD-BD
• Make sure to cut off all phases of the power supply externally before attempting
installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
INSTALLATION
PRECAUTIONS
Unit: mm(inches)
• Use the product within the generic environment specifications described in PLC
main unit manual (Hardware Edition).
[5]
Connector cover is
Never use the product in areas with excessive dust, oily smoke, conductive dusts,
removed
corrosive gas (salt air, Cl
impacts, or exposed to high temperature, condensation, or rain and wind.
[7]
If the product is used in such conditions, electric shock, fire, malfunctions,
deterioration or damage may occur.
• When drilling screw holes or wiring, make sure cutting or wire debris does not
enter the ventilation slits.
MASS(Weight): 20g(0.05lbs)
Failure to do so may cause fire, equipment failures or malfunctions.
• Do not touch the conductive parts of the product directly.
Doing so may cause device failures or malfunctions.
• Connect expansion board securely to their designated connectors.
Loose connections may cause malfunctions.
The following section describes the installation method for the FX
(FX
-40M . In this example).
3G
Turn off the power to the PLC before installation.
For more details on installation and removal, refer to the PLC main unit manual.
→ Refer to the FX
2.1 Installation Method
1) Remove the top cover (A in the right
figure) or top cover (S) (A' in the right
figure).
In a 14/24-point type main unit, only
the top cover (A in the right figure) is
provided.
2) Attach the accessory side cover (B in
the right figure).
Attachment of the side cover (B in the
right figure) is not necessary when
installing the FX
3G
-2AD-BD to only
under the top cover (S) of a 40/60-
point type main unit.
3) Make sure the expansion board is in
parallel with the main unit and attach it
to the optional equipment connector.
4) Fix the expansion board to the main
unit using the provided M3 tapping
screws. (2 places)
Tightening torque : 0.3 to 0.6 N⋅m
3. Wiring
3G
Series User's Manual - Hardware Edition.
WIRING
PRECAUTIONS
• Make sure to cut off all phases of the power supply externally before
attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
WIRING
PRECAUTIONS
• Make sure to cut off all phases of the power supply externally before
attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.
• Make sure to observe the following precautions in order to prevent any
damage to the machinery or accidents due to abnormal data written to the
, H
S, SO
, or NO
), flammable gas, vibration or
2
2
2
2
PLC under the influence of noise:
1) Do not bundle the main circuit line together with or lay it close to the main
circuit, high-voltage line or load line.
Otherwise, noise disturbance and/or surge induction are likely to take
place. As a guideline, lay the control line at least 100mm (3.94") or more
away from the main circuit or high-voltage lines.
2) Ground the shield wire or shield of the shielded cable at one point on the
PLC. However, do not use common grounding with heavy electrical
systems.
• Make sure to properly wire to the European terminal board in accordance
with the following precautions.
Failure to do so may cause electric shock, a short-circuit, wire breakage, or
Series PLC
3G
damage to the product.
- The disposal size of the cable end should be 9mm (0.35").
- Tightening torque should be between 0.22 and 0.25N
Series User's Manual - Hardware Edition
3G
- Twist the end of strand wire and make sure that there are no loose wires.
- Do not solder-plate the electric wire ends.
- Do not connect more than the specified number of wires or electric wires
A
of unspecified size.
- Affix the electric wires so that neither the terminal block nor the connected
A'
1)
parts are directly stressed.
1)
• Make sure to properly wire to the FX
following precautions.
4)
3)
Failure to do so may cause electric shock, a short-circuit, wire breakage, or
4)
B
damage to the product.
- The disposal size of the cable end should follow the dimensions described
in this manual.
3)
2)
- Tightening torque should follow the specifications in this manual.
3.1 Applicable Cable and Terminal Tightening Torque
3.1.1
Terminal block (European type)
1) Wire size
Wiring to analog device should use 20-22 AWG wire.
2) Applicable cable
Single-wire
2-wire
3) Termination of cable end
Strip the coating of strand wire and twist the cable core before connecting it,
or strip the coating of single wire before connecting it.
An alternative connection is to use a ferrule with insulating sleeve.
Phoenix Contact Co., Ltd.
- Strand wire/single wire
When using a stick terminal with insulating sleeve, choose a wire with proper
cable sheath referring to the above outside dimensions, or otherwise, the
wire cannot be inserted easily.
The tightening torque must be 0.22 to 0.25N
m.
3G
Series PLC in accordance with the
Type
Wire size
0.3mm
2
to 0.5mm
2
(AWG22 to 20)
2 pieces of 0.3mm
2
(AWG22)
Manufacturer
Model
Pressure bonding tool
CRIMPFOX ZA 3
AI 0.5-8WH
(or CRIMPFOX UD 6)
- Stick terminal with insulating sleeve
Contact area
Insulation sleeve
(Crimping area)
9mm
8mm
(0.35")
(0.31")
2.6mm(0.1")
14mm(0.55")
m.

Advertisement

loading

Summary of Contents for Mitsubishi FX3G-2AD-BD

  • Page 1 How to obtain manuals An alternative connection is to use a ferrule with insulating sleeve. For product manuals or documents, consult with the Mitsubishi Electric dealer from who you purchased your product. Manufacturer...
  • Page 2 55°C) Warranty 180μs Mitsubishi will not be held liable for damage caused by factors found not to be conversion (The data will be updated at every scan time of the PLC.) the cause of Mitsubishi; opportunity loss or lost profits caused by faults in the time Mitsubishi products;...
  • Page 3 55°C) Warranty 180μs Mitsubishi will not be held liable for damage caused by factors found not to be conversion (The data will be updated at every scan time of the PLC.) the cause of Mitsubishi; opportunity loss or lost profits caused by faults in the time Mitsubishi products;...