Fitting Slider Handle To Control Cam (Fs); Fitting The Battery Into Spark Ignition Generator (Fs); Checking The Ignition Operation - Valor 500FS Installer And Owner Manual

Inset live fuel effect gas fire
Table of Contents

Advertisement

Slider Control (FS) Models
9.5 Fitting slider handle to control cam.
The Chrome slider handle needs to be
fitted to the cam assembly as shown, with
the two M4 x 8mm screws provided.
9.6 Fitting the battery into the spark ignition generator.
At the front of the electronic spark generator there is a
removable circular battery cover. Unscrew the cover in an
anticlockwise direction.
Remove any protective film from the battery if applicable and
place into the generator. The negative (-) terminal should go
in first. The battery is marked with (+).
Screw back on the cap.

9.7 Checking the ignition operation.

Push the slider handle to the LEFT as far as
-
possible till the ignition is visible, several sparks
should be generated and heard between the
electrode and pilot tip.
If there are no sparks check the following:
-
Ensure that the electrode lead is connected
-
to the terminal at the base of the electrode.
If the above is correct, check for damage to
-
the electrode lead and that the battery has
been correctly fitted.
©