Gas Consumption; Operating Your Fire; The Oxysafe Flame Sensing And Flue Blockage Safety System - Valor 500FS Installer And Owner Manual

Inset live fuel effect gas fire
Table of Contents

Advertisement

Natural Gas - 500RC
Has a maximum (HIGH) NG input of 5.55kw (Gross)
Has a minimum (LOW) NG input of 3.2kw (Gross)
Natural Gas - 500FS
Has a maximum (HIGH) NG input of 5.55kw (Gross)
Has a medium (MED) NG input of 3.7kw (Gross)
Has a minimum/Ignition (LOW) NG input of 2.7kw (Gross)
When operating your fire for the first time, some vapours may be given off which may
cause a slight odour and could possibly set off any smoke alarms in the immediate
vicinity. These vapours are quite normal with new appliances. They are totally harmless
and will disappear after a few hours use.

The Oxysafe flame sensing and flue blockage safety system.

For your safety, this appliance is fitted with a flue blockage safety device which will
shut down the appliance in the event of abnormal flue conditions.
This device is NOT a substitute for an independently mounted Carbon
Monoxide detector.
The device will also automatically shut off the gas supply to the fire if the pilot flame
goes out due to lack of oxygen or for any other reason.
If this device starts to repeatedly shut off the gas, get expert advice.
This device incorporates a probe which senses that the heat from the pilot flame is
correct. If this probe is cool, the device will prevent any gas flow unless the control
knob is held in at the ignition position.
If, for any reason, the flames go out when the fire is hot or if the fire is turned off
when hot, always wait at least three minutes before attempting to relight.
©
GDC Group Ltd. SEPT 2016

GAS CONSUMPTION

OPERATING YOUR FIRE

PLEASE NOTE
Page 50