Fitting The Log Fuel Effect; Burner And Supply Pipe Installation; Burner Installation; Supply Pipe Installation - Valor 500FS Installer And Owner Manual

Inset live fuel effect gas fire
Table of Contents

Advertisement

INSTALLER GUIDE
12.4 Fitting the fuel effect.
The installer and owner guide for the ceramic fuel effect is supplied in a seperate
booklet. It is important that the fitting guide for the ceramic fuel effect be placed inside
or attached to this guide and handed to the customer following completion of the
'Final review' section.

13. BURNER AND SUPPLY PIPE INSTALLATION

13.1 Burner installation.

1. Remove the 'Aeration checking' reminder label from the top of the burner.
2. Refit the burner unit to the convection box with the two screws removed previously.
NOTE: Do not tighten down fully these two screws as it can cause the burner
tray to lift at the front interfering with later assembly. The screws only need to
be tightened to prevent the tray from moving forward.

13.2 Supply pipe installation.

1. A nut and olive is provided for an 8mm-pipe inlet connection directly to the gas
control. The isolating 'T' connector can be rotated to allow a connection from the rear.
The 'T' connector includes a valve for isolating the gas supply.
The supply pipe must be rigid material. Flexible pipe must not be used. Connect the
supply line to the appliance.
2. If closed
open the isolating valve at the inlet 'T' connector.
,
3. Turn on the gas supply and pressure check the installation pipework for gas
soundness. In the United Kingdom (GB) check in accordance with the current edition
of BS 6891. In the Republic of Ireland check in accordance with the current edition of
IS 813 "Domestic Gas Installations".
Some burner operations can be checked at this stage. Checking now will mean that
less disassembly will be required if any problems are found. A full check should still
be made, however, after final installation. Only leave the burner alight long
enough to confirm its operation.

13.3 Burner checks.

13.3.1 Lighting the fire.
If closed
open the isolating 'T' connector valve.
,
Remote control models - 600RC & 800 RC
- Reference the remote control handset operation
manual.
Press and hold the 'ON/OFF' button until two short beeps
-
(acoustic signal) and a blinking series of lines confirms the
start sequence has begun; release button.
©