INSTALLER GUIDE

18.13 To remove the thermocouple interrupter block (RC models only).
1. Remove the burner unit (See section 18.7).
2. Detach the thermocouple from the interrupter block by unscrewing the
thermocouple nut.
3. Detach the two leads from the interrupter block making sure to pull on the base of
the tabs and not the leads. It is important that when replacing the leads that the lead
with the larger tag (From the receiver) is furthest away from the valve body.
4. Remove the interrupter block by unscrewing from the gas shut-off tap.
5. Refit in the reverse order. If the leads cannot be easily attached to the interrupter
block when it is fully tightened to the gas shut-off tap, slacken it and rotate to allow
the leads to be fitted. Retighten making sure that the leads remain in place in the
interrupter block. Fit and tighten the thermocouple nut making sure that the leads are
secured in the interrupter block to give a good electrical contact. Do not over tighten
the thermocouple nut.

18.14 To replace the burner (s).

1. Remove the burner unit (See section 18.7).
2. Unscrew and remove the burner clamping plate from the upper right hand side of
the burner. Remove all three screws for ease (See figure 38).
3. Unscrew and remove the injector cover plate from underneath the burner (See
figure 39).
4. Support the elbow injector and unscrew the injector nut.
5. Lift the right hand side of the burner, slide it to the right and lift clear
6. Refit in reverse order.

18.15 To remove the burner injector.

1. Remove the burner (See section 18.7).
2. Unscrew the injector from the burner.
3. Refit in the reverse order.

18.16 To remove the appliance from the fireplace.

1. Follow steps 18.1 - 18.8.
2. The inlet cover must be removed to allow the fire to be removed. Remove the
screws holding the cover inplace and any tape that has been added so that the hole
in the rear of the fire is clear to allow the 'T' connector and pressure test point
clearance to pass through.
3. If the fire retention is as method 1 (See section 11.1 of this guide), remove the 6
screws.
If the fire retention is as method 2 (See section 11.2 of this guide), slacken the
hexagonal adjusters on the cable retainers and unscrew the thumbscrews to release
the cables.
4. Remove the convector box from the fireplace.
5. Refit as described in the relevant installation sections. Make sure gas soundness,
sealing, spillage test and performance are satisfactory.
©