Private MIB Parameters
Table C‐2: Private MIB Parameters (Sheet 17 of 32)
Name
winlink1000OduPerfMonEthInterva
lTable
winlink1000OduPerfMonEthInterva
lEntry
winlink1000OduPerfMonEthInterva
lIdx
winlink1000OduPerfMonEthInterva
lRxMBytes
winlink1000OduPerfMonEthInterva
lTxMBytes
winlink1000OduPerfMonEthInterva
lEthCapacityThreshUnder
winlink1000OduPerfMonEthInterva
lHighTrafficThreshExceed
winlink1000OduPerfMonEthInterva
lActiveSeconds
winlink1000OduPerfMonEthDayTab
le
winlink1000OduPerfMonEthDayEnt
ry
winlink1000OduPerfMonEthDayIdx
winlink1000OduPerfMonEthDayRx
MBytes
winlink1000OduPerfMonEthDayTx
MBytes
winlink1000OduPerfMonEthDayEth
CapacityThreshUnder
winlink1000OduPerfMonEthDayHig
hTrafficThreshExceed
winlink1000OduPerfMonEthDayAct
iveSeconds
winlink1000OduPerfMonTdmCurrTa
ble
winlink1000OduPerfMonTdmCurrE
ntry
winlink1000OduPerfMonTdmCurrA
ctiveSeconds
winlink1000OduPerfMonTdmInterv
alTable
winlink1000OduPerfMonTdmInterv
alEntry
winlink1000OduPerfMonTdmInterv
alIdx
winlink1000OduPerfMonTdmInterv
alActiveSeconds
winlink1000OduPerfMonTdmDayTa
ble
RADWIN 2000 C Plus User Manual
OID
Type
1.3.6.1.4.1.4458.1000.1.6.1
Gauge
0.1.1
Release  3.5.70
Description
N/A This table defines/keeps the ethernet counters 
of the last day (in resolution of 15 min intervals). 
N/A This is an entry in the Interval Table.   INDEX 
{ifIndex  winlink1000OduPerfMonEthIntervalIdx 
RO
This table is indexed per interval number. Each 
interval   is of 15 minutes and the oldest is 96. 
RO
Current RX Mega Bytes per interval. 
RO
Current Transmit Mega Bytes per interval. 
RO
The number of times throughput was below 
threshold in the each interval.   Relevant for 
point to point systems. 
RO
The number of times actual traffic was above 
threshold in the each interval. 
RO
The number of seconds in which RPL Ethernet 
service was not blocked in the each interval. 
N/A This table defines/keeps the ethernet counters 
of the last month (in resolution of days). 
N/A This is an entry in the Days Table.   INDEX 
{ifIndex  winlink1000OduPerfMonEthDayIdx } 
RO
This table is indexed per Day number. Each 
interval   is of 15 minutes and the oldest is 96. 
RO
Current RX Mega Bytes per day. 
RO
Current Transmit Mega Bytes per day. 
RO
The number of times throughput was below 
threshold each day.   Relevant for point to point 
systems. 
RO
The number of times actual traffic was above 
threshold each day. 
RO
The number of seconds in which RPL Ethernet 
service was not blocked each day. 
N/A This table defines/keeps the TDM counters of 
the current 15 min interval. 
N/A This is an entry in the Current Interval Table.   
INDEX {ifIndex } 
RO
Parameter indicating whether the TDM service 
was active.    Under TDM backup link  the 
parameter indicates whether     the backup link 
was active. 
N/A This table defines/keeps the TDM counters of 
the last day (in resolution of 15 min intervals). 
N/A This is an entry in the Interval Table.   INDEX 
{ifIndex  
winlink1000OduPerfMonTdmIntervalIdx } 
RO
This table is indexed per interval number. Each 
interval   is of 15 minutes and the oldest is 96. 
RO
Parameter indicating whether the TDM service 
was active.   Under TDM backup link  the 
parameter indicates whether    the backup link 
was active. 
N/A This table defines/keeps the TDM counters of 
the last month (in resolution of days). 
Chapter C
C‐22