Radwin 2000 C PLUS User Manual page 250

Point to point broadband wireless
Hide thumbs Also See for 2000 C PLUS:
Table of Contents

Advertisement

Private MIB Parameters
Table C‐2: Private MIB Parameters (Sheet 12 of 32)
Name
winlink1000OduAirSpectrumChann
elScanned
winlink1000OduAirSpectrumChann
elScanningTimestamp
winlink1000OduAirSpectrumChann
elLastNFAntennaA
winlink1000OduAirSpectrumChann
elLastNFAntennaB
winlink1000OduAirSpectrumChann
elAverageNFAntennaA
winlink1000OduAirSpectrumChann
elAverageNFAntennaB
winlink1000OduAirSpectrumChann
elMaxNFAntennaA
winlink1000OduAirSpectrumChann
elMaxNFAntennaB
winlink1000OduAirSpectrumChann
elCACPerformed
winlink1000OduAirSpectrumChann
elLastCACTimestamp
winlink1000OduAirSpectrumChann
elRadarDetected
winlink1000OduAirSpectrumChann
elRadarDetectionTimestamp
winlink1000OduAirSpectrumChann
elAvailable
winlink1000OduAirSpectrumChann
elMaxBeaconRss
winlink1000OduAirSpectrumChann
elCompressed
winlink1000OduAirChipMinMaxFre
q
winlink1000OduAirSpectrumAnalysi
sTimeout
winlink1000OduAirAntConfAndRate
sStatus
winlink1000OduAirDualAntTxMode 1.3.6.1.4.1.4458.1000.1.5.5
RADWIN 2000 C Plus User Manual
OID
Type
1.3.6.1.4.1.4458.1000.1.5.5
Integer
6.5.1.3
1.3.6.1.4.1.4458.1000.1.5.5
TimeTicks
6.5.1.4
1.3.6.1.4.1.4458.1000.1.5.5
Integer
6.5.1.5
1.3.6.1.4.1.4458.1000.1.5.5
Integer
6.5.1.6
1.3.6.1.4.1.4458.1000.1.5.5
Integer
6.5.1.7
1.3.6.1.4.1.4458.1000.1.5.5
Integer
6.5.1.8
1.3.6.1.4.1.4458.1000.1.5.5
Integer
6.5.1.9
1.3.6.1.4.1.4458.1000.1.5.5
Integer
6.5.1.10
1.3.6.1.4.1.4458.1000.1.5.5
Integer
6.5.1.11
1.3.6.1.4.1.4458.1000.1.5.5
TimeTicks
6.5.1.12
1.3.6.1.4.1.4458.1000.1.5.5
Integer
6.5.1.13
1.3.6.1.4.1.4458.1000.1.5.5
TimeTicks
6.5.1.14
1.3.6.1.4.1.4458.1000.1.5.5
Integer
6.5.1.15
1.3.6.1.4.1.4458.1000.1.5.5
Integer
6.5.1.16
1.3.6.1.4.1.4458.1000.1.5.5
OctetString
6.5.1.17
1.3.6.1.4.1.4458.1000.1.5.5
DisplayString
6.6
1.3.6.1.4.1.4458.1000.1.5.5
Integer
7
Integer
8
Release  3.5.70
Description
RO
An indication of the vaildity of the channel's 
data.  If the channel was scanned the data is 
valid, else not.
RO
Channel last scan timestamp  in hundredths of a 
second  since device up time.    If the channel 
was not scanned than the return value will be 0. 
RO
Normalized Noise Floor value in dBm ‐ of 
Antenna A ‐ (including 2 neighbor frequencies). 
RO
Normalized Noise Floor value in dBm ‐ of 
Antenna B ‐ (including 2 neighbor frequencies). 
RO
Average normalized Noise Floor value in dBm ‐ 
of Antenna A ‐  over all dwells. 
RO
Average normalized Noise Floor value in dBm ‐ 
of Antenna B ‐  over all dwells. 
RO
Max normalized Noise Floor value in dBm ‐ of 
Antenna A ‐  over all dwells. 
RO
Max normalized Noise Floor value in dBm ‐ of 
Antenna B ‐  over all dwells. 
RO
Was CAC performed on the channel.
RO
Last CAC performed timestamp  in hundredths 
of a second  since device up time.    If no CAC has 
performed on the channel  the return value will 
be 0. 
RO
Was Radar detected on the channel.
RO
Last Radar Detection timestamp  in hundredths 
of a second  since device up time.    If no Radar 
has detected on the channel  the return value 
will be 0. 
RO
Is the channel available for use.
RO
The max RSS value of a received beacon on the 
specific channel in dBm. 
RO
Compress all the Spectrum data per channel 
into one variable.   Frequency (4 bytes)   
Scanned (1 byte)   Timestamp (4 bytes)   Last NF 
Antenna A (1 byte)   Last NF Antenna B (1 byte)   
Avg NF Antenna A (1 byte)   Avg NF Antenna B (1 
byte)   Max NF Antenna A (1 byte)   Max NF 
Antenna B (1 byte)   CAC Performed (1 byte)   
Last CAC Timestamp (4 bytes)   Radar Detected 
(1 byte)   Radar Detected Timestamp (4 bytes)   
Channel Available (1 byte)   Max Beacon RSS (1 
byte). 
RO
The minimum and maximum frequencies in 
MHz which the chip supports. 
RW Spectrum analysis timeout in seconds. 
RO
Description: Antenna configuration and Rates 
status (1 = Single antenna with single data  
stream  2 = Dual antenna with single data 
stream  3 = Dual antenna with dual data  
stream). 
RW Description: Transmission type when using Dual 
radios (MIMO or AdvancedDiversity using  one 
stream of data). 
Chapter C
C‐17

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2000 C PLUS and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents