RW 2000 Series Installation Guide Document Version 12.0 June 2023 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Connecting the Laptop to an ODU ................ 21 3.3.1 Connecting a Laptop to 2000‐Plus (LFF, SFF and Alpha 6.4) ODUs ....22 3.3.2 Connecting a Laptop to RADWIN 2000 Alpha INT ODUs ....... 23 3.3.3 Connecting a Laptop to RADWIN 2000 Alpha EMB ODUs ......23 3.3.4 Connecting a Laptop to RADWIN 2000 E ODUs ..........
Page 3
Mounting an ODU on a Standard Mounting Kit ..........39 3.7.6 Mounting the Dish Antenna and Bracket on a Standard Mounting Kit .... 44 Installing the RADWIN 2000 Alpha EMB Mounting Kit and Mounting the ODUs ..44 3.8.1 Installing the RADWIN 2000 Alpha EMB Mounting Kit ........44 3.8.2...
Page 4
For Norway and Sweden only ..............125 8.7.9 Norway ......................125 8.7.10 Sweden ......................125 8.7.11 Unregulated ....................125 8.7.12 Safety Practices ................... 125 8.7.13 Maritime coating ..................126 June 2023 Page 4 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 5
June 2023 Page 5 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
RADWIN 2000 Family Configuration Guide. 1.2 RADWIN 2000-Plus Family Overview The RADWIN 2000‐Plus Family delivers up to 2.2Gbps (depending on the specific model) in a point‐to‐point architecture and is the ideal choice for last-mile enterprise connectivity, short-distance backhaul, and high‐end applications.
Some options and models may not be available for your regulatory environment. 1.2.1 Outdoor Units (ODUs) There are six types of outdoor ODUs (radio units): • Large Form Factor (LFF) ‐ With an integrated or external antenna. June 2023 Page 7 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 8
Small Form Factor (SFF) ‐ As its name implies, this ODU is smaller than an LFF ODU but can also have an integrated or external antenna. June 2023 Page 8 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 9
Figure 6 SFF ODU external dimensions • RADWIN 2000 Alpha EMB ODUs ‐ Uses a smaller form factor than that of the LFF or SFF. Can also have either: o an integrated antenna ‐ the Turbo Gain antenna - that installs directly on the ODU.
Page 10
• RADWIN 2000 Alpha Integrated 5.x and RADWIN 2000 Alpha Integrated 3.x (integrated antenna) ODUs ‐ Uses a larger form‐factor than that of the RADWIN 2000 Alpha EMB ODU. Figure 10 RADWIN 2000 Alpha Integrated 5.x & RADWIN 2000 Alpha Integrated 3.x...
Page 11
Figure 11 RADWIN 2000 Alpha Integrated 5.x and RADWIN 2000 Alpha Integrated 3.x ODU external dimensions • RADWIN 2000 Alpha Integrated 6.4 – this type is available in two models, both with integrated antenna: o 28dBi o 25dBi This type has the same enclosure as the LFF model.
Page 12
Figure 14 Alpha Connectorized ODU external dimensions With the exception of the frequency band, the RADWIN 2000 Alpha Integrated 5.x, 3.x and 6.4 are identical in form factor and function. We will use the term RADWIN 2000 Alpha Integrated to refer to all ODUs.
Page 13
RADWIN 2000 E ODUs are available in two forms: o An external ODU that requires a connection to an external antenna: o An integrated ODU that includes an antenna: June 2023 Page 13 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
For simplicity, Lightning Protection Units (LPUs) are not shown in the following figure, but they are recommended. See Mounting and Connecting the LPUs for directions on how to install the LPUs. June 2023 Page 14 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 15
For dying gasp, the PoE voltage must be >= 55 V). Dying Gasp is supported: • On Alpha EXT, Alpha INT 500M • On SU PRO EXT and INT with latest HW version. June 2023 Page 15 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 16
Subsequently, a single PN is available for each HW version of the radio, without needing to create multiple PNs (dedicated PN for each regulation). The same radio device can be transferred from one regulation zone to another. June 2023 Page 16 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
1.2.3 Management Tools To configure your system, you need to connect an ODU to a PC running either RADWIN Manager or use the browser user interface, depending on the ODU as follows: •...
Page 18
Emphasize a special feature. • Provide additional background. Caution: Risk of damage to equipment or of service degradation. Warning: Risk of danger to persons operating near the equipment. June 2023 Page 18 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Use extreme care when installing antennas near power lines • Use extreme care when working at heights • When using an AC power source for RADWIN devices, always use the AC power adapter supplied by RADWIN • Use the right tools! •...
2.5 Internal ESD Protection Circuits RADWIN equipment is designed to meet the ETSI/FCC/Aus/NZ/CSA EMC and Safety requirements. To fulfill these requirements, the system's Telecom lines at the ODU/PoE are Transformer‐isolated and include internal ESD (Electro‐Static‐Discharge) Protection circuits. When installing an AC powered HSU: To maintain Overvoltage (Installation) Category II, install a suitable surge suppressor device in the branch circuit to limit expected transients to Overvoltage Category II values.
Checking Items to be Installed Preparing Tools Installation Installing the Standard Mounting Kit and Mounting the ODUs/Installing the RADWIN 2000 Alpha EMB Mounting Kit and Mounting the ODUs/Mounting Alpha Connectorized ODUs Grounding the ODUs 12. Mounting and Connecting the LPUs...
2. Connect an ethernet cable between the laptop ethernet port and the PoE IN or LAN socket. 3. Connect the PoE OUT or PoE socket to the appropriate ODU socket. June 2023 Page 22 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Connecting a Laptop to RADWIN 2000 E ODUs 3.3.1 Connecting a Laptop to 2000‐Plus (LFF, SFF and Alpha 6.4) ODUs 1. Connect to the IDU socket. June 2023 Page 23 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Figure 22 Integrated ODU - POE IN socket 3.4 Configuring the ODUs for Connectivity As described in Management Tools , either the RADWIN Manager or the browser user interface is used for configuration, depending on the ODU model as follows: •...
• Configuring RADWIN 2000‐Plus (LFF or SFF ODUs for Connectivity • Configuring RADWIN 2000, Alpha EMB and RADWIN 2000 Alpha INT ODUs (3.x, 5.x and 6.4) for Connectivity • Configuring RADWIN 2000 E ODUs for Connectivity 3.4.1 Configuring RADWIN 2000‐Plus (LFF or SFF ODUs for Connectivity 1.
Page 27
3. Install the RADWIN Manager. 4. Log on to the RADWIN Manager as an "Installer", enter the default IP address (http://10.0.0.120) and password: wireless. 5. From the RADWIN Manager, click the Configure icon: 6. Select the Management tab. 7. Enter new IP address, Subnet Mask, and Default Gateway in the indicated fields.
2. In a browser, enter its IP address (default value: 10.0.0.120). 3. In the login page, enter the following credentials: o username: admin June 2023 Page 28 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
If this ODU hasn’t yet been activated, the Quick Setup wizard starts automatically. Otherwise the Home page appears. • If the Quick Setup wizard hasn’t started, click Quick Setup. The wizard for configuring the initial device parameters appears: June 2023 Page 29 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 30
ODU gets a GPS fix and the configured band is not permitted according to the regulation in the detected country. o Configure Link Configuration parameters: i. For Client: June 2023 Page 30 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
External antenna + mounting kit (if using an external antenna for LFF or SFF ODUs).+ Bracket (for Radwin Dish antenna with alpha/E) • RF cables (if using an external antenna for LFF or SFF ODUs) June 2023 Page 31 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
• Turbo Gain antenna (if using this antenna for the RADWIN 2000 Alpha EMB ODU) 3.6 Preparing Tools • Crimping tool (required only if you installers are preparing cables) • Spanner/wrench 13mm (1/2") • Cable ties • Sealing material •...
Page 33
Flange Nut from the mounting kit. 3. Loosen both M8X90 Hex Head Screws by rotating both M8 Flange Nuts until the end of the Hex Head Screw. June 2023 Page 33 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 34
6. Open the Pole Clamp allowing the ODU Holder to attach onto the pole, then close the Pole Clamp on the M8X90 Hex Head Screw. Thin Vertical Pole ¾” ‐1½” Medium Vertical Pole 2 - 3” June 2023 Page 34 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 35
1. Remove the mounting kit from the ODU packaging box. 2. Remove the M8X40 Hex Head Screw and the M8 Flange Nut from the mounting kit. June 2023 Page 35 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 36
Nm until the mounting kit is firmly on the ODU. 6. Tighten both worm drive clamps using a screwdriver until the ODU is secure on the pole. June 2023 Page 36 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 37
Insert the ODU Vertical Adapter into the ODU hole. Tighten the M8 Flange Nut with a torque of 15 Nm until the mounting kit is firmly on the ODU. June 2023 Page 37 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 38
Pole Clamp on the M8X90 Hex Head Screw. 7. Tighten both M8 Flange Nuts with a torque of 15 Nm until firmly secured on the pole. June 2023 Page 38 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
3.7.3 Installing the Standard Mounting Kit on a Wall 1. Remove the mounting kit from the ODU packaging box. 2. Dissemble all parts from the ODU Holder. June 2023 Page 39 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
3.7.4 Various ODUs Mounting Options on a Standard Mounting Kit LFF (large form‐factor) ODUs, SFF (small form‐factor) ODUs, RADWIN 2000 Alpha INT ODUs, RADWIN 2000 E ODUs, as well as external PoEs, RADWIN GSUs, and external antennas can use the mounting kit as shown in the following figures.
Page 41
Figure 23 Mounted LFF & Alpha 6.4 ODU Figure 24 Mounted SFF ODU or GSU June 2023 Page 41 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 42
Figure 25 Mounted RADWIN 2000 Alpha INT ODU Figure 26 Mounted RADWIN 2000 E External ODU June 2023 Page 42 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 43
For a flat panel antenna, a mounting kit adapter is required: Figure 29 Flat panel antenna mounting kit adapter 1. Attach the mounting kit adaptor to the rear of the external antenna: June 2023 Page 43 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 44
3. Attach the mounting bolt to the side of the adaptor with the recess. The following figure shows a mounted antenna. Figure 31 Flat Panel antenna ‐ mounted on a pole June 2023 Page 44 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Mounting the RADWIN 2000 Alpha EMB ODU 3.8.1 Installing the RADWIN 2000 Alpha EMB Mounting Kit The RADWIN 2000 Alpha EMB ODU has its own mounting kit. Mount this ODU as follows: 1. Place the mount on a pole or wall: 2.
Page 46
Slide the metal band through the mount. c. Slide the metal band through the clamp. d. Adjust the radius of the band, and lock it with the clamp. June 2023 Page 46 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
1. Open the clamp (for ODU). 2. Position the ODU so that the knobs on the mounting ball on the rear are opposite the slots on the mount. June 2023 Page 47 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 48
3. Firmly place the ODU into the mount until you hear a click. June 2023 Page 48 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
5. Keep the clamp half‐closed until the alignment procedure is complete. 3.9 Mounting Alpha Connectorized ODUs The Alpha Connectorized ODU is mounted on a pole using worm‐drive clamps. 1. Place the ODU on a pole. June 2023 Page 49 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 50
2. Fasten the ODU to the pole using the worm‐drive clamps. June 2023 Page 50 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
3.10.1 Before You Start Before installing any RADWIN equipment, make sure you have the results of the site survey you conducted. For guidelines on how to conduct a site survey, see the RADWIN 5000 Site Survey application note. Examples of grounding and lightning protection regulations are: •...
Page 52
Lightning Protection Guide by Dehn International (www.dehn‐international.com). An example of designing an air-termination system: 1. Take a composite 3D diagram (or use an actual model) of the installation neighborhood. Example: June 2023 Page 52 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 53
Equipment in this zone are still not immune from the effects of EMD, but they are significantly reduced. • Further details relating to rolling sphere and risk assessment can be found in IEC/EN62305 and IEC 61024‐1. June 2023 Page 53 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 54
An example of grounding connections and shielding appears in the following figures. The following figures are examples. Your installation will have its own specific configuration. Figure 33 Grounding for Pole-Mounted ODUs June 2023 Page 54 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 55
Figure 34 Grounding for Wall-Mounted ODUs June 2023 Page 55 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 56
Figure 35 Grounding for Rooftop-Mounted ODUs June 2023 Page 56 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 57
ODUs also meets the requirements and local electrical earthing regulations. • RADWIN does not provide a warranty for equipment damaged by electromagnetic discharge (EMD). If the guidelines provided here and local relevant regulations are followed, the chances of damage from lightning (EMD) can be drastically reduced.
The design of all installations must include the appropriate addition of both ground bonding and surge/LPUs to better protect equipment and reduce network outages. • RADWIN recommends using two LPUs for each ODU installation: one near the ODU and one near the PoE. •...
3.10.4 Grounding the ODUs LFF and Alpha 6.4 ODUs Figure 37 Ground: LFF ODU SFF ODUs Figure 38 Ground: SFF ODU June 2023 Page 59 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 60
Figure 39 Ground: RADWIN 2000 Alpha INT ODU RADWIN 2000 Alpha EMB ODUs Since the RADWIN 2000 Alpha EMB is grounded via its mounting kit, the mount must be grounded before the ODU is mounted. Figure 40 Ground: RADWIN 2000 Alpha EMB ODU...
Page 61
Alpha Connectorized ODUs Figure 41 Ground: Alpha Connectorized ODU RADWIN 2000 E ODUs Figure 42 Ground: RADWIN 2000 E External ODU June 2023 Page 61 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Figure 43 Ground: RADWIN 2000 E Integrated ODU 3.10.5 Mounting and Connecting the LPUs RADWIN recommends using LPUs for each ODU installation as follows: • one near the ODU • one near the PoE Make sure the LPU is oriented with the cable glands oriented towards the bottom.
Page 63
Mount the LPUs as follows: 1. Insert the metal band through the slots on the LPU. June 2023 Page 63 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 64
2. Tighten the metal band: 3. Connect the grounding lug to a ground source. June 2023 Page 64 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 65
4. Remove the cable glands, and thread the CAT‐5e cables through them. June 2023 Page 65 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 66
6. Route one CAT‐5e cable up to the ODU, and the other down to the PoE (via the lower LPU). An LPU installed on a pole is shown below. June 2023 Page 66 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
RADWIN 2000 E External ODU 3.11.1 Connecting LFF and SFF ODUs to an External Antenna Connect the external antenna to the antenna connections on the ODU as shown. June 2023 Page 67 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
3.11.2 Connecting RADWIN 2000 Alpha EMB ODUs to an External Antenna Turbo Gain Antenna Fasten the Turbo Gain antenna on the RADWIN 2000 Alpha EMB ODU using these steps: 1. Connect the cables to the ODU. 2. Seal the cables (see Waterproofing ).
External, Non‐Integrated Antenna To connect an external, non‐integrated antenna to the RADWIN 2000 Alpha EMB ODU: 1. Connect the cables to the ODU. 2. Seal the cables using ScotchTM 23 splicing tape or similar.
3.11.4 Connecting RADWIN 2000 E External ODUs to an External Antenna 1. Connect the external antenna to the antenna connections on the ODU as shown. June 2023 Page 70 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
3.12 Connecting the ODUs 3.12.1 Connecting LFF, SFF, RADWIN 2000 Alpha INT, and Alpha Connectorized ODUs When working with the Alpha Connectorized ODU: • Hazardous 56VDC voltage may appear on accessible antenna connections. Use Personal Protection Equipment (e.g. insulating gloves) when working with the ODU or the antenna.
Page 72
Figure 45 Input port: SFF ODU (connection label: "IDU") Figure 46 Input port: RADWIN 2000 Alpha INT ODU (no label) June 2023 Page 72 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 73
1. Connect the CAT‐5e cable from the lower LPU to the "Out" port. 2. Connect the LAN cable to the "In" port. 3. Connect the power cable. June 2023 Page 73 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Ground the PS before applying power. 3.12.2 Connecting RADWIN 2000 Alpha EMB ODUs Connect a CAT‐5e cable to the input port of the ODU, as follows: June 2023 Page 74 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 75
1. Open the rear cover of the RADWIN 2000 Alpha EMB. 2. Insert a CAT‐5e cable into the input port. 3. Close the rear cover tightly. June 2023 Page 75 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
5. Fasten the CAT‐5e cable connections with a gland and add sealant tape. 6. Connect the ground cable to the ground. 7. Perform the final connections via the RADWIN 2000 Alpha EMB PoE: 8. Connect the CAT‐5e cable from the lower LPU to the "PoE" port.
Page 77
4. Connect the ground cable to the ground. 5. Perform the final connections to the PoE depending on the type of PoE you are using, as described below. June 2023 Page 77 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 78
SFP cable - connect the SFP cable directly to the ODU SFP (labeled “LAN”) port. 2. Connect the ground cable. 3. Connect the power cable to the outdoor PoE. DC Injector June 2023 Page 78 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Ground the PS before applying power. 3.13 Waterproofing This section does not apply to the RADWIN 2000 Alpha EMB ODU. 1. Protect all outdoor connections from rain, dust, moisture and salt by taping the cable/gland connection with an appropriate sealant tape. RADWIN recommends using Scotch™...
Page 80
June 2023 Page 80 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Connect a laptop to the ODU. 2. From the NOC: a. Keep the PoE connected to the LAN. 3. In the CLI, ping the ODU using the ODU's IP address. June 2023 Page 81 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
You must define one ODU as an RT‐A(HBS) or Hub before you can activate it (see Differences Between RT‐A(HBS) and RT‐B(HSU)). As described in Management Tools , use either the RADWIN Manager or the browser user interface, depending on the ODU model. 5.1 Configuring RADWIN 2000‐Plus ODUs as RT- A(HBS) 1.
5.2 Configuring RADWIN 2000 Alpha and RADWIN Alpha Connectorized ODUs as Hubs RADWIN Manager release 11.0 and above detects if the managed device supports the browser UI, and if so, redirects to use the browser UI instead. 1. Connect to ODU: o From a laptop in the field, disconnect the PoE from the communications network (LAN Connection) and connect the laptop.
Page 84
June 2023 Page 84 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
6. Activating the RT‐A (HBS)/Hub • Activating RADWIN 2000‐Plus RT-A(HBS) ODUs • Activating RADWIN 2000 Alpha and RADWIN Alpha Connectorized Hub ODUs • Activating RADWIN 2000 E Hub ODUs 6.1 Activating RADWIN 2000‐Plus RT-A(HBS) ODUs 1. Connect to ODU: o From a laptop in the field, disconnect the PoE from the communications network (LAN connection) and connect the laptop.
8. The main window displays a brief message saying the action was completed successfully, and after a short time, the ODU is activated. 6.3 Activating RADWIN 2000 E Hub ODUs The RADWIN 2000 E is automatically activated when you click FINISH at the end of the Quick Setup wizard. June 2023 Page 86 Corporate Headquarters | T.
While swiveling the ODU, listen to the buzzer beep sequence until the optimal alignment is achieved (3 beeps and a pause, as shown below). 2. Repeat the above in elevation. June 2023 Page 87 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
The subscriber ODU will stop beeping when it is aligned with the base station and configured. • You can use the RSS indicator on the main window of the RADWIN Manager for a more accurate indication of the signal strength. •...
Swivel the ODU 90-° to the right slowly, 180° to the left, and then 90° back towards the base station. Note at which point the RSS value is maximum. b. Repeat the above in elevation. June 2023 Page 89 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
7.2.2 Swivelling a RADWIN 2000 Alpha EMB mount 1. Swivel the mounts as shown following: Figure 54 Swivel horizontally Figure 55 Swivel vertically 2. Once alignment is complete, tighten the arm on the RADWIN 2000 Alpha EMB mounting kit. June 2023 Page 90...
Figure 56 Tighten arm on mount: RADWIN 2000 Alpha EMB ODU 3. If the ODU requires more tightening, use the hex screw with a 5mm hex key. Figure 57 Use hex screw to further tighten arm on mount 7.2.3 Swivelling a RADWIN 2000 Alpha INT mount 1.
Page 92
Figure 58 Swivel horizontally Figure 59 Swivel vertically 2. Once alignment is complete, tighten the bolt as shown in the following figure: June 2023 Page 92 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Figure 60 Tighten bolt 7.2.4 Swivelling ODUs with an External Antenna 1. Loosen the external antenna bolt, swivel as required then tighten the bolt. June 2023 Page 93 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Figure 61 Tighten bolt as shown 7.2.5 Fine Alignment of the RT‐A(HBS)/Hub To improve the alignment, RADWIN recommends that you repeat the above alignment procedure for the RT‐A(HBS)/Hub opposite the RT‐B(HSU)/Client based on RSS level measurements. 7.3 Aligning RADWIN 2000 E ODUs Antenna alignment is performed while the Client is not Registered.
Page 95
4. When you decide that the alignment is the best attainable, lock the bolts. Alignment is now complete. 5. To start the data service between the Hub and the Client, click Register. June 2023 Page 95 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Bidirectional Forwarding Detection. A network protocol used to detect faults between two forwarding engines connected by a link. Base Station: an ODU that can transmit and receive to more than one point. See also . June 2023 Page 96 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 97
In our case, this is usually: System Tx Power + Antenna Gain ‐ Cable Loss. Federal Aviation Administration. A U.S. federal office that manages aviation regulations throughout the United States. June 2023 Page 97 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 98
Multiple In, Multiple Out: A technique by which the capacity of a radio link is increased using multiple transmitting and receiving antennas, transmitting a different signal on all antennas. June 2023 Page 98 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 99
Quality of Service. Smart Bandwidth Management. Sector A group of ODUs that consists of one HBS and several HSUs that communicate with the HBS. June 2023 Page 99 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 100
BWA purposes. Uplink Data traffic from an HSU to an HBS, or Data traffic from an RT‐B to an RT‐A. Vehicular Mobile Unit. June 2023 Page 100 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
White/Green Rx T Green Tx T White/Orange Tx N Orange Blue Power White/Blue Power White/Brown Power Brown Power GbE PoE RJ 45 Connector Pinout ‐ ‐ June 2023 Page 101 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
The pinout is for the HSS Unit, used in serial HSS. HBS/HSS Unit Connection Pinout Color ODU RJ‐45 HSS UNIT RJ‐45 White/Green Green Not connected White/Orange Orange Blue White/Blue June 2023 Page 102 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
8.3.2 About Single and Dual Antennas Each RADWIN 2000‐Plus Family ODU is made of two radio transceivers (radios). The radios make use of algorithms that utilize both Spatial Multiplexing and Diversity resulting in enhanced capacity, range and link availability. The number of antennas used is determined by user configuration and by automatic system decisions, explained below.
Page 104
For example, at 80MHz CBW, using a dual antenna, a RADWIN 2000 D‐Plus ODU can transmit at modulation of 256QAM and FEC of 5/6 and can get an air rate of 866.7 Mbps, compared to 433.3 Mbps with a single antenna.
The Tx Power (system) shows the total transmission power of the ODU and is used to calculate the EIRP according to regulations. • To see the relationship between Tx Power (radio) and Tx Power (system), note that: June 2023 Page 105 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
éléments sous tension. Mise à la terre Tous les produits RADWIN doivent être mis à la terre pendant l'usage courant. La mise à la terre est assurée en reliant la fiche d'alimentation à une prise de courant avec une protection de terre.
être de 14 mm avec un conduit de 16 mm. 8.4.2 Installation sur pylône et mur L' ODU ou l'O‐PoE peuvent être montés sur un pylône ou un mur. June 2023 Page 107 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 108
Contenu du kit de montage ODU Le kit de montage ODU comprend les pièces suivantes: Figure 62 Contenu du kit de montage ODU Montage sur un pylône June 2023 Page 108 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 109
4. Attacher l'antenne au pylône en utilisant les deux courroies de fixation . Ajuster l'inclinaison nécessaire en utilisant l'échelle angulaire et serrer tous les boulons et écrous à la position requise. June 2023 Page 109 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 112
Radio devices labeled FCC ID: Q3K‐5AXCULC‐X / IC: 5100A‐5AXCULCX (RADWIN 2000 Alpha EMB) The RADWIN 2000 Alpha EMB must be installed so as to provide a minimum separation distance from bystanders as specified in the following tables: Frequency Band 5725‐5850 MHz Cat.
Page 113
10.0° RW‐9614‐ 5359 Radio devices labeled FCC ID: Q3K‐5XSUALMOD / IC: 5100A‐5XSUALMOD (RADWIN 2000 Alpha INT and Alpha Connectorized ODUs) Radio transmitters with this label have been approved by Innovation, Science and Economic Development Canada to operate with the antenna types listed below, with the maximum permissible gain indicated.
Page 114
The input impedance of all antennas is 50 Ohm. The RADWIN 2000 Alpha INT and Alpha Connectorized ODUs must be installed so as to provide a minimum separation distance from bystanders as specified in the following tables: Frequency Band 5725‐5850 MHz Cat.
8.5.2 For Deployment in EU Member States RADWIN 2000‐Plus Family ETSI Products RADWIN 2000-Plus Family ETSI products must be installed so as to provide a minimum separation distance from bystanders as specified in the following table: Frequency Band Antenna gain Min.
Page 116
[GHz] [dBi] [cm] RADWIN 2000 Alpha EMB The RADWIN 2000 Alpha EMB must be installed so as to provide a minimum separation distance from bystanders as specified in the following tables: Frequency Band 5725‐5875 MHz Gain (dBi) Tx Power per chain Min.
Consult the dealer or an experienced radio/TV technician for help. Changes or modifications to this equipment not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. June 2023 Page 118 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 119
Indoor Units comply with part 15 of the FCC rules. Operation is subject to the following two conditions: 1. These devices may not cause harmful interference. 2. These devices must accept any interference received, including interference that may cause undesired operation. June 2023 Page 119 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 120
La radio doit être installée et utilisée en stricte conformité avec les instructions du fabricant décrites dans ce guide. Toute autre installation ou utilisation du produit enfreint les règlements de l'ISDE règlements. June 2023 Page 120 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 121
In Canada Radio Local Area Network Devices Operating in the 5150‐5250 MHz Frequency Band may only be allowed following licensing process. Au Canada, les appareils du réseau local radio fonctionnant dans la bande de June 2023 Page 121 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 122
Radio devices shall be so installed to have worst‐case tilt angle to remain compliant with the EIRP elevation mask requirement set forth in RSS‐247. Section 6.2.2(3). June 2023 Page 122 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Page 123
Radio devices subject to RSS‐247 issue 2 shall not be capable of transmitting in the band 5600‐5650 MHz. Dispositifs radio soumis a la delivrance RSS‐247 2 ne sont pas capables de transmettre dans la bande 5600‐5650 MHz. June 2023 Page 123 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
003 du Canada. ‐ 8.7.4 EU – Compliance Radio transmitters operating in the EU need to comply the RE‐DIRECTIVE 2014/53/EU, EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU. June 2023 Page 124 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
All RADWIN products that operate in the 5.8 GHz band comply with the requirements of the harmonized standard ETSI EN 302 502 and the ECC RECOMMENDATION (06)04 The 3.5 GHz band complies with the standard ETSI EN 302 326‐2 V1.2.2 and draft...
A Primary Protector is not required to protect the exposed wiring as long as the exposed wiring length is limited to less than or equal to 140 feet, and instructions are June 2023 Page 126 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
5. Earth the antenna coax shield to the building earth or mast. 8.7.13 Maritime coating Products are tested and approved according to IEC-60068-2-11 Test Ka: Salt mist. June 2023 Page 127 Corporate Headquarters | T. +972.3.766.2900 | E. sales@radwin.com | www.radwin.com...
Need help?
Do you have a question about the RW 2000 Series and is the answer not in the manual?
Questions and answers