Creating A Program - Mitsubishi MELSEC Q Series User Manual

Cc-link system master/local module
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

11 COMMUNICATION BETWEEN THE MASTER STATION AND LOCAL
STATIONS

11.2.4 Creating a program

Master station
Master station
Ver.2 compatible
PLC CPU
buffer memory
X100F to X1000
RX00F to RX000
X101F to X1010
RX01F to RX010
X102F to X1020
RX02F to RX020
X103F to X1030
RX03F to RX030
X104F to X1040
RX04F to RX040
X105F to X1050
RX05F to RX050
X106F to X1060
RX06F to RX060
X107D to X1070
RX07F to RX070
RX08F to RX080
X108F to X1080
X109F to X1090
RX09F to RX090
RX0AF to RX0A0
X10AF to X10A0
X10BF to X10B0
RX0BF to RX0B0
X10CF to X10C0
RX0CF to RX0C0
X10DD to X10D0
RX0DF to RX0D0
Y100F to Y1000
RY00F to RY000
Y101F to Y1010
RY01F to RY010
Y102F to Y1020
RY02F to RY020
Y103F to Y1030
RY03F to RY030
Y104F to Y1040
RY04F to RY040
Y105F to Y1050
RY05F to RY050
Y106F to Y1060
RY06F to RY060
Y107D to Y1070
RY07F to RY070
Y108F to Y1080
RY08F to RY080
Y109F to Y1090
RY09F to RY090
Y10AF to Y10A0
RY0AF to RY0A0
Y10BF to Y10B0
RY0BF to RY0B0
Y10CF to Y10C0
RY0CF to RY0C0
Y10DD to Y10D0
RY0DF to RY0D0
The last two bits cannot be used for communication between the master and local stations.
11 - 25
This section shows the program to be used for communication between the master
and local stations. The following diagram shows the relationship between the devices
of the master station PLC CPU and the devices of the local station PLC CPU.
The shaded areas indicate the devices that are actually used.
[Remote input (RX) and remote output (RY)]
Ver.1compatible local station
(station number 1: occupies 4 stations)
RY00F to RY000
RY01F to RY010
RY02F to RY020
RY03F to RY030
RY04F to RY040
RY05F to RY050
RY06F to RY060
RY07F to RY070
RX00F to RX000
RX01F to RX010
RX02F to RX020
RX03F to RX030
RX04F to RX040
RX05F to RX050
RX06F to RX060
RX07F to RX070
Ver.2compatible local station
(station number 5: occupies 2 stations: double)
Local station
PLC CPU
Y100F to Y1000
Y101F to Y1010
Y102F to Y1020
Y103F to Y1030
Y104F to Y1040
Y105F to Y1050
Y106F to Y1060
Y107D to Y1070
X100F to X1000
X101F to X1010
X102F to X1020
X103F to X1030
X104F to X1040
Ver.2 compatible
X105F to X1050
buffer memory
X106F to X1060
X107D to X1070
RY00F to RY000
RY01F to RY010
RY02F to RY020
RY03F to RY030
RY04F to RY040
RY05F to RY050
RY06F to RY060
RY07F to RY070
RY08F to RY080
RY09F to RY090
RY0AF to RY0A0
RY0BF to RY0B0
RY0CF to RY0C0
RY0DF to RY0D0
RX00F to RX000
RX01F to RX010
RX02F to RX020
RX03F to RX030
RX04F to RX040
RX05F to RX050
RX06F to RX060
RX07F to RX070
RX08F to RX080
RX09F to RX090
RX0AF to RX0A0
RX0BF to RX0B0
RX0CF to RX0C0
RX0DF to RX0D0
MELSEC-Q
Local station
PLC CPU
Y100F to Y1000
Y101F to Y1010
Y102F to Y1020
Y103F to Y1030
Y104F to Y1040
Y105F to Y1050
Y106F to Y1060
Y107D to Y1070
Y108F to Y1080
Y109F to Y1090
Y10AF to Y10A0
Y10BF to Y10B0
Y10CF to Y10C0
Y10DD to Y10D0
X100F to X1000
X101F to X1010
X102F to X1020
X103F to X1030
X104F to X1040
X105F to X1050
X106F to X1060
X107D to X1070
X108F to X1080
X109F to X1090
X10AF to X10A0
X10BF to X10B0
X10CF to X10C0
X10DD to X10D0
11 - 25

Hide quick links:

Advertisement

Table of Contents
loading