6 PARAMETER SETTINGS

6.3.4 Local station automatic refresh parameter settings

6 - 15
(1) The following describes an example of the parameter settings. See (2) for actual
settings.
(2) Set the automatic refresh parameters using the following procedure.
(a) Set the remote input (RX) refresh device using "Remote input (RX)".
Default value : None
Setting range: Device name - Select from X, M, L, B, D, W, R or
Example) Set to X1000.
(b) Set the remote output (RY) refresh device using "Remote output (RY)".
Default value : None
Setting range: Device name - Select from Y, M, L, B, T, C, ST, D,
Example) Set to Y1000.
(c) Set the remote register (RWr) refresh device using "Remote register (RWr)".
Default value : None
Setting range: Device name - Select from M, L, B, D, W, R, or ZR.
Example) Set to W0.
ZR.
Device number - Within the range of the device
points that the CPU has.
W, R or ZR.
Device number - Within the range of the device
points that the CPU has.
Device number - Within the range of the device
points that the CPU has.
MELSEC-Q
6 - 15