Sign In
Upload
Manuals
Brands
Mitsubishi Manuals
Control Systems
QJ61BT11N
Mitsubishi QJ61BT11N Manuals
Manuals and User Guides for Mitsubishi QJ61BT11N. We have
1
Mitsubishi QJ61BT11N manual available for free PDF download: User Manual
Mitsubishi QJ61BT11N User Manual (464 pages)
CC-Link System Master/Local Module
Brand:
Mitsubishi
| Category:
Control Systems
| Size: 5.66 MB
Table of Contents
Safety Precautions
3
Revisions
7
Table of Contents
8
Conformation to the EMC Directive and Low Voltage Instruction
15
About the Generic Terms and Abbreviations
16
Product Components
18
1 Overview
19
Compatibility with CC-Link
20
Features
20
2 System Configuration
31
Applicable System
34
Applicable Modules and Number of Cpus that Can be Mounted
34
Notes on the System Configuration
36
How to Check the Function Version
38
CC-Link Version
39
3 Specifications
40
Performance Specifications
40
Maximum Overall Cable Distance (for Ver. 1.00)
42
Maximum Overall Cable Distance (for Ver. 1.10)
44
CC-Link Dedicated Cable
45
4 Functions
47
Function List
47
Basic Functions
49
Communication with the Remote I/O Stations
49
Communication with the Remote Device Stations
51
Communication with the Local Stations
56
Communication with the Intelligent Device Stations
62
Parameter Setting with GX Developer
68
Parameter Setting with Dedicated Instruction
69
Functions for Improving System Reliability
71
Disconnecting Data Link Faulty Stations and Continuing the Data Link with Only Normal Stations
71
(Slave Station Cut-Off Function)
71
Automatically Reconnecting a Disconnected Data Link Faulty Station When It Returns to Normal
72
(Automatic Return Function)
72
Continuing the Data Link When an Error Occurs in the Master Station PLC CPU (Data Link Status Setting When the Master Station PLC CPU Has an Error)
73
Retaining the Device Status of a Data Link Faulty Station (Setting the Status of Input Data from a Data Link Faulty Station)
74
Clearing Data in Case of PLC CPU STOP
75
Continuing the Data Link Even When the Master Station Is Faulty
77
(Standby Master Function)
77
Handy Functions
91
Simplifying the Initialization Procedure Registration of Remote Device Stations (Remote Device Station Initialization Procedure Registration Function)
91
Performing High-Speed Processing (Event Issuance for the Interrupt Program)
94
Enabling the Data Link Simply by Powering on (Automatic CC-Link Startup)
97
Communicating with Intelligent Device Stations (Remote Net Mode)
99
Speeding up the Response from Remote I/O Stations (Remote I/O Net Mode)
100
Creating a Program that Contains Modules to be Added in the Future (Reserved Station Function)
101
Powering off a Station in Operation Without Error Detection
102
Synchronizing the Link Scan with the Sequence Scan (Scan Synchronous Function)
103
Replacing Modules Without Error Detection (Temporary Error Invalid Station Setting Function)
107
Checking Operations for each Local Station (Data Link Stop/Restart)
108
Station Number Overlap Checking Function
109
Multiple PLC System Support
110
Reducing the Reserved Points of the Remote I/O Stations (Remote I/O Station Points Setting)
111
Increasing the Number of Cyclic Points (Remote Net Ver.2 Mode)
113
Transient Transmission Functions
121
Performing Transient Transmission (Dedicated Instructions)
121
5 Data Link Processing Time
122
Link Scan Time
122
Transmission Delay Time
125
Master Station Remote I/O Station
125
Master Station Intelligent Device Station
155
Processing Time for Dedicated Instructions
156
Master Station Local Station
156
Local Station Local Station
159
Master Station Intelligent Device Station
160
Link Refresh Time
161
Master Station/Local Station
161
Station Status at Error Occurrence
165
Status of the Master Station, Standby Master Station (When the Master Station Is Operating) and Remote I/O Station at Error Occurrence
165
Status of the Remote Device Station, Local Station, Standby Master Station (When the Local Station Is Operating) and Intelligent Device Station at Error Occurrence
166
6 Parameter Settings
167
Procedure from Parameter Settings to Data Link Startup
167
CPU Parameter Area and Master Module Parameter Memory
167
Procedure from Parameter Settings to Data Link Startup with GX Developer
168
Procedure from Parameter Settings to Data Link Startup with Dedicated Instruction
168
Parameter Setting Items
169
Example of Parameter Settings with GX Developer (Remote Net Ver.1 Mode)
171
Master Station Network Parameter Settings
171
Master Station Automatic Refresh Parameter Settings
176
Local Station Network Parameter Settings
178
Local Station Automatic Refresh Parameter Settings
181
Example of Parameter Settings with GX Developer (Remote Net Ver.2 Mode)
183
Master Station Network Parameter Settings
183
Master Station Automatic Refresh Parameter Settings
188
Local Station Network Parameter Settings
190
Local Station Automatic Refresh Parameter Settings
193
Example of Parameter Settings with GX Developer (Remote Net Additional Mode)
195
Master Station Network Parameter Settings
195
Master Station Automatic Refresh Parameter Settings
200
Local Station Network Parameter Settings
203
Local Station Automatic Refresh Parameter Settings
206
Example of Parameter Settings with GX Developer (Remote I/O Net Mode)
209
Master Station Network Parameter Settings
209
Master Station Automatic Refresh Parameter Settings
212
Example of Parameter Setting with Dedicated Instruction
214
7 Procedure before Starting the Data Link
219
Installation
221
Handling Precautions
221
Installation Environment
222
Part Identification Nomenclature and Settings
222
Checking the Module Status (Hardware Test)
225
Connecting the Modules Using the CC-Link Dedicated Cables
227
Wiring Check
228
T-Branch Connection with the CC-Link Dedicated Cable
229
T-Branch System Configuration
229
T-Branch Communication Specifications List
230
Switch Settings
231
Station Number Setting
231
Transmission Rate and Mode Settings
232
Checking the Connection Status (Line Test)
233
8 Programming
237
Precautions on Programming
237
I/O Signals for the PLC CPU
238
I/O Signal List
238
Details of the I/O Signals
240
Buffer Memory
241
Buffer Memory List
241
Buffer Memory Details
244
Link Special Relays and Registers (SB/SW)
262
Link Special Relays (SB)
262
Link Special Registers (SW)
267
Mode Selection Method
276
9 Communication between the Master Station and Remote I/O Stations
277
When Remote I/O Net Mode Is Used
277
Configuring a System
277
Setting the Master Station
278
Setting the Remote I/O Stations
279
Setting the Master Station Parameters
280
Setting the Network Parameters of the Master Station
280
Setting the Automatic Refresh Parameters of the Master Station
282
Creating a Program
283
Performing the Data Link
285
Confirming the Operation with the LED Display
285
Confirming the Operation with the Sequence Program
286
10 Communication between the Master Station and Remote Device Stations
287
When Remote Net Ver. 1 Mode Is Used
287
Configuring a System
287
Setting the Master Station
288
Setting the Remote Device Station
289
Setting the Master Station Parameters
290
Setting the Network Parameters of the Master Station
290
Setting the Automatic Refresh Parameters of the Master Station
292
Initial Setting of the Remote Device Station
293
Setting the Target Station Number
293
Setting the Regist Procedure Registration
293
Validating the Remote Device Station Initial Settings
297
Creating a Program
299
Performing the Data Link
302
Confirming the Operation with the LED Display
302
Confirming the Operation with the Sequence Program
303
When Remote Net Ver. 2 Mode Is Used
304
Configuring a System
304
Setting the Master Station
305
Setting the Remote Device Station
306
Setting the Master Station Parameters
308
Setting the Network Parameters of the Master Station
308
Setting the Automatic Refresh Parameters of the Master Station
310
Initial Setting of the Remote Device Station
311
Setting the Target Station Number
311
Setting the Regist Procedure Registration
311
Validating the Remote Device Station Initial Settings
315
Creating a Program
318
Performing the Data Link
322
Confirming the Operation with the LED Display
322
Confirming the Operation with the Sequence Program
323
When Remote Net Additional Mode Is Used
324
Configuring a System
324
Setting the Master Station
325
Setting the Remote Device Station
326
Setting the Master Station Parameters
328
Setting the Network Parameters of the Master Station
328
Setting the Automatic Refresh Parameters of the Master Station
330
Initial Setting of the Remote Device Station
331
Setting the Target Station Number
331
Setting the Regist Procedure Registration
331
Validating the Remote Device Station Initial Settings
335
Creating a Program
338
Performing the Data Link
342
Confirming the Operation with the LED Display
342
Confirming the Operation with the Sequence Program
343
11 Communication between the Master Station and Local Stations
344
When Remote Net Ver. 1 Mode Is Used
344
Configuring a System
344
Setting the Master and Local Stations
345
Setting the Master Station Parameters
346
Setting the Network Parameters of the Master Station
346
Setting the Automatic Refresh Parameters of the Master Station
348
Setting the Local Station Parameters
349
Setting the Network Parameters of the Local Station
349
Setting the Automatic Refresh Parameters of the Local Station
351
Creating a Program
352
Master Station Program
354
Local Station Program
354
Performing the Data Link
355
Confirming the Operation with the LED Display
355
Confirming the Operation with the Sequence Program
356
When Remote Net Ver. 2 Mode Is Used
357
Configuring a System
357
Setting the Master and Local Stations
358
Setting the Master Station Parameters
359
Setting the Network Parameters of the Master Station
359
Setting the Automatic Refresh Parameters of the Master Station
361
Setting the Local Station Parameters
362
Setting the Network Parameters of the Ver.1 Compatible Local Station (Station Number 1)
362
Setting the Automatic Refresh Parameters of the Ver.1 Compatible Local Station (Station Number 1)
364
Setting the Network Parameters of the Ver.2 Compatible Local Station (Station Number 5)
365
Setting the Automatic Refresh Parameters of the Ver.2 Compatible Local Station (Station Number 5)
367
Creating a Program
368
Master Station Program
370
Local Station Program
370
Performing the Data Link
371
Confirming the Operation with the LED Display
371
Confirming the Operation with the Sequence Program
372
When Remote Net Additional Mode Is Used
373
Configuring a System
373
Setting the Master and Local Stations
374
Setting the Master Station Parameters
375
Setting the Network Parameters of the Master Station
375
Setting the Automatic Refresh Parameters of the Master Station
377
Setting the Local Station Parameters
378
Setting the Network Parameters of the Ver.1 Compatible Local Station (Station Number 1)
378
Setting the Automatic Refresh Parameters of the Ver.1 Compatible Local Station (Station Number 1)
380
Setting the Network Parameters of the Ver.2 Compatible Local Station (Station Number 5)
381
(Station Number 5)
381
Creating a Program
384
Master Station Program
386
Local Station Program
386
Performing the Data Link
387
Confirming the Operation with the LED Display
387
Confirming the Operation with the Sequence Program
388
12 Communication between the Master Station and Intelligent Device Stations
389
13 Troubleshooting
391
Verification Upon Problem Occurrence
391
Troubleshooting Procedures When the "ERR." LED of the Master Station Is Flashing or When Normal Data Cannot be Sent/Received During Data Link
398
Error Codes
400
CC-Link Diagnostics Using the GX Developer
406
Appendix
412
Appendix 1 External Dimensions Diagram
412
Appendix 2 Dedicated Instruction List
413
Appendix 2.1 RIRD Instruction
414
Appendix 2.2 RIWT Instruction
422
Appendix 2.3 RIRCV Instruction
424
Appendix 2.4 RISEND Instruction
429
Appendix 2.5 RIFR Instruction
434
Appendix 2.6 RITO Instruction
437
Appendix 2.7 RLPASET Instruction
440
Appendix 3 Differences between the New and Previous Models
451
Appendix 4 Precautions When Changing from AJ61QBT11 to QJ61BT11N
452
Appendix 5 Precautions When Changing from QJ61BT11 to QJ61BT11N
452
Appendix 6 CPU-Dependent Function Availability
453
Appendix 7 Parameter Setting Checklist
454
Appendix 7.1 Parameter Setting Checklist
454
Appendix 7.2 Station Information Setting Checklist
455
Advertisement
Advertisement
Related Products
Mitsubishi QJ61BT11
Mitsubishi MELSEC QJ61CL12
Mitsubishi MELSEC QJ71C24-R2
Mitsubishi MELSEC QJ71C24N
Mitsubishi QJ71NT11B
Mitsubishi QJ71MB91
Mitsubishi QJ71BR11
Mitsubishi QJ72LP25G
Mitsubishi QJ71GP21S-SX
Mitsubishi QJ71GP21-SX
Mitsubishi Categories
Air Conditioner
Controller
Projector
Automobile
Engine
More Mitsubishi Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL