About The Generic Terms And Abbreviations - Mitsubishi MELSEC Q Series User Manual

Cc-link system master/local module
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

About the Generic Terms and Abbreviations

This manual uses the following generic terms and abbreviations to describe the QJ61BT11N CC-Link
System Master/Local Module, unless otherwise specified.
Generic Term/Abbreviation
QJ61BT11N
Cyclic transmission
Transient transmission
Master station
Local station
Remote I/O station
Remote device station
Remote station
Intelligent device station
Standby master station
Slave station
Master/local module
Master module
Local module
Remote module
Intelligent device module
Remote I/O net mode
Remote net mode
Remote net ver. 1 mode
Remote net ver. 2 mode
Remote net additional mode
Ver. 1 compatible slave station
Ver. 2 compatible slave station
A - 14
Abbreviation for QJ61BT11N CC-Link System Master/Local Module
Transmission method by which to periodically communicate the contents of remote
I/O and remote registers.
Transmission method with which the counterpart is specified and 1:1 communication
is used at an arbitrary timing.
Station that controls the data link system.
One master station is required for each system.
Station having a PLC CPU and the ability to communicate with the master and other
local stations.
Remote station that handles bit unit data only. (Performs input and output with
external devices.) (AJ65BTB1-16D, AJ65SBTB1-16D)
Remote station that handles bit unit and word unit data only. (Performs input and
output with external devices, and analog data conversion.)
(AJ65BT-64AD, AJ65BT-64DAV, AJ65BT-64DAI)
Generic term for remote I/O station and remote device station.
(Controlled by the master station)
Station that can perform transient transmission, such as the AJ65BT-R2 (including
local stations).
Backup station for data link control when the link to the master station is disconnected
due to a PLC CPU or power supply problem.
Generic term for remote I/O station, remote device station, local station, intelligent
device station and standby master station.
Generic term for QJ61BT11N, QJ61BT11, AJ61BT11, A1SJ61BT11, AJ61QBT11,
and A1SJ61QBT11
Generic term for QJ61BT11N, QJ61BT11, AJ61BT11, A1SJ61BT11, AJ61QBT11,
and A1SJ61QBT11 when they are used as master stations.
Generic term for QJ61BT11N, QJ61BT11, AJ61BT11, A1SJ61BT11, AJ61QBT11,
and A1SJ61QBT11 when they are used as local stations.
Generic term for AJ65BTB1-16D, AJ65SBTB1-16D, AJ65BT-64AD, AJ65BT-64DAV,
AJ65BT-64DAI, and A852GOT
Module that can perform transient transmission, such as the AJ65BT-R2 (including
local module).
Dedicated mode for sending and receiving data to and from the remote I/O station at
high speed.
Mode that can communicate with all stations used for CC-Link (remote I/O station,
remote device station, local station, intelligent device station, and standby master
station)
The remote net mode has three different modes: remote net ver. 1 mode, remote net
ver. 2 mode, and remote net additional mode.
Mode in which complete compatibility with the conventional module (QJ61BT11) is
achieved.
Select this mode when the number of cyclic points need not be increased or when the
QJ61BT11N is used to replace the conventional module as a maintenance product.
Select this mode when increasing the number of cyclic points and configuring a new
system.
Select this mode when adding a ver. 2 compatible station to the existing system to
increase the number of cyclic points.
Slave station compatible with the remote net ver. 1 mode.
Slave station compatible with the remote net ver. 2 mode.
Description
A - 14

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qj61bt11n

Table of Contents