10 COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE
DEVICE STATIONS
Status confirmation of AJ65VBTCU-68ADV, AJ65VBTCU-68DAVN
AJ65VBTCU-68ADV initial setting
AJ65VBTCU-68ADV initial setting change
Initial setting change
AJ65VBTCU-68ADV initial setting processing
AJ65VBTCU-68DAVN initial setting
The program enclosed by the dotted line is necessary only when the initial settings are changed.
10 - 30
REMARK
Setting with the sequence program (Reference)
For reference, an example setting performed with the sequence program is shown
below.
(To the next page)
MELSEC-Q
AJ65VBTCU-68ADV,
AJ65VBTCU-68DAVN
data link normal
AJ65VBTCU-68ADV data
link abnormal
AJ65VBTCU-68DAVN data
link abnormal
AJ65VBTCU-68ADV
A/D conversion enable/
prohibit specification
(RWw0)
CH.1 to CH.4 input
range setting (RWw1)
Average processing
specification (RWw3)
CH.2 average time,
number of times setting
(RWw5)
Turns on initial data
processing completion flag
(RY18).
Turns on initial data
setting request flag (RY19).
A/D conversion enable/
prohibit specification
(RWw0)
CH.1 to CH.4 input
range setting (RWw1)
Average processing
specification (RWw3)
CH.2 average time,
number of times setting
(RWw5)
Turns on initial data
setting request flag (RY19).
Turns off initial data
processing completion flag
(RY18).
Turns off initial data setting
request flag (RY19).
AJ65VBTCU-68DAVN
Analog output enable/
disable setting (RWw8)
CH.1 to CH.4 output range
setting (RWw9)
HOLD/CLEAR setting
(RWwB)
Turns on initial data
processing completion flag
(RY18).
Turns on initial data
setting request flag
(RY19).