Setting Parameter Value
Parameter set mode is entered by pressing ENTER. In set mode, value is underlined. Value is
altered by pressing the UP/DOWN buttons. The modified value is stored by pressing ENTER.
Modifications can be cancelled and set mode inactivated by pressing MENU.
accept and store
(( ÃG6IBV6B@
(( ÃG6IBV6B@
ENTER
alter
ENTER
(1*/,6+
(1*/,6+
value
exit without saving
MENU
Note! In parameter set mode the cursor blinks when the parameter value is altered.
Note! To view the parameter default value in the parameter set mode, press the UP/DOWN buttons
simultaneously.
Menu Functions
Scroll the Menu for desired menu function, then press and hold ENTER down until the display
blinks to start the operation.
Note! Parameter copying does not affect all parameters. The excluded parameters are: 9901,
9905-9910, 1605, 1607, 5002, 5201 and all Group 51 parameters. See "ACS 400 Complete
Parameter List" on page 65 for a description of these parameters.
Copy Parameters from Drive to Panel (upload)
Press & hold
8PQ`ÃUPÃQ6I@G
8PQ`DIB
ENTER
0(18
/2&
Note! The drive must be stopped and in local control. Parameter 1602
must be
PARAMETER LOCK
set to 1 (
).
OPEN
ACS 400 User's Manual
27