Mounting The Acs 400 On A Wall - ABB ACS 400 User Manual

Ac drives for speed control
Hide thumbs Also See for ACS 400:
Table of Contents

Advertisement

C Mounting the ACS 400 on a Wall
Warning! Before installing the ACS 400, ensure the input power supply to the drive is off.
1
The lid of the packing-box provides a Wall Mounting
Template.
Remove the lid from the box.
2
The ACS 400 should only be mounted vertically on a
smooth, solid surface, free from heat, dampness, and
condensation. Ensure minimum air flow gaps of 8 in
(200 mm) above and below, and 2 in (50 mm) around
the sides of the unit.
1 Using the mounting template, mark the position of
the mounting holes.
2 Drill the holes.
3 Screw in four screws or affix nuts and bolts
(depending on the mounting surface).
3
IP 21
Position the ACS 400 onto the mounting screws or
bolts and securely tighten in all four corners.
Note! Lift the ACS 400 by its metal chassis.
IP 54
1 Remove the front cover, see Figure 10.
2 Remove the rubber plugs by pushing from outside.
3 Screw in the screws.
4 Replace the rubber plugs.
6
Figure 4
Figure 5
Figure 6
Figure 7
http://nicontrols.com
Removing the wall mounting template.
Marking and drilling the mounting holes.
Mounting type IP21 drives.
Mounting type IP54 drives.
ACS 400 User's Manual

Advertisement

Table of Contents
loading

Table of Contents