ABB ACS 400 User Manual page 136

Ac drives for speed control
Hide thumbs Also See for ACS 400:
Table of Contents

Advertisement

Code Description
5 = DI5
Interlocks function is in use. Depending on the number of motors, the digital inputs are reserved for the
interlock signals according to the following table.
No of aux. motors
(param. 8117)
0
1
2
3
6 =
EXTERNAL IO
Interlocks function is in use. All interlock signals are taken through external I/O modules. Depending on the
number of motors, the digital inputs are reserved for the interlock signals according to the following table.
No of aux. Motors
(param. 8117)
0
1
2
3
Interlock signals are active low, i.e. an interlock is active when the corresponding interlock signal is absent.
If a start command is given when the interlock signal of the speed regulated motor is active, the ACS 400
will not start, and will show alarm 30 (INTERLOCK) on the control panel.
Each Interlock circuit should be wired as follows:
1. A contact of the On/Off switch of the motor must be wired to the Interlock circuit. PFC logic detects if a
motor is switched off. The logic does not try to start the switched-off motor; the next available motor is
started instead.
2. A contact of the motor thermal relay (or another protective device in the motor circuit) must be wired to
the Interlock input. PFC logic detects if the thermal relay is activated. The motor is stopped.
ACS 400 User's Manual
ACS 400 digital
inputs
DI1-DI4: free
DI5: Motor 1
DI1-DI4: free
DI5: Motor 1
DI1-DI4: free
DI5: Motor 1
DI1-DI4: free
DI5: Motor 1
ACS 400 digital
inputs
DI1-DI5: free
DI1-DI5: free
DI1-DI5: free
DI1-DI5: free
http://nicontrols.com
Interlock signals
NDIO module 1
Not used
DI1: Motor 2
DI2: Unused
DI1: Motor 2
DI2: Motor 3
DI1: Motor 2
DI2: Motor 3
Interlock signals
NDIO module 1
DI1: Motor 1
DI2: Unused
DI1: Motor 1
DI2: Motor 2
DI1: Motor 1
DI2: Motor 2
DI1: Motor 1
DI2: Motor 2
NDIO module 2
Not used
Not used
Not used
DI1: Motor 4
DI2: Unused
NDIO module 2
Not used
Not used
DI1: Motor 3
DI2: Unused
DI1: Motor 3
DI2: Motor 4
125

Advertisement

Table of Contents
loading

Table of Contents