32 Mechanical installation

Mounting the drive on the wall

Units without vibration dampers

1.
Mark the locations for the four holes. The mounting points are shown in
Dimensional drawings
the mounting template on the package.
2. Install the screws or bolts in the marked locations.
3. IP55 (UL type 12) units: Remove the front cover.
4. Position the drive onto the screws on the wall. Note: Lift the drive by its chassis
(R6: by its lifting holes), not by its cover.
5. Tighten the screws in the wall.
IP55 (UL 12)
3
IP55 (UL type 12) marine applications (+C132) of frame sizes R4 to
R6
ACS800-01/U1 Marine Supplement
See

Units with vibration dampers (+C131)

ACS800-01/U1 Vibration Damper Installation Guide
See

UL 12 units

Install the hood delivered with the drive 50 mm (2.0 in.) above the top of unit.
(page 133). In frame sizes R2 to R5 (IP21, UL type 1), use
1
[3AFE68291275 (English)].
[3AFE68295351 (English)].