B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 8 of 71)
ADDR
REGISTER NAME
21A8
Breaker flashover 1 supervision phase C
21AA
Breaker flashover 1 block
21AC
Breaker flashover 1 events
21AD
Breaker flashover 1 target
21AE
Reserved (4 items)
B
21B2
...Repeated for breaker flashover 2
Breaker Arcing Current Actuals (Read Only Non-Volatile) (6 modules)
21E0
Breaker 1 Arcing Current Phase A
21E2
Breaker 1 Arcing Current Phase B
Breaker Arcing Current Actuals (Read Only Non-Volatile) (6 modules)
21E4
Breaker 1 Arcing Current Phase C
Breaker Arcing Current Actuals (Read Only Non-Volatile) (6 modules)
21E6
Breaker 1 Operating Time Phase A
21E7
Breaker 1 Operating Time Phase B
Breaker Arcing Current Actuals (Read Only Non-Volatile) (6 modules)
21E8
Breaker 1 Operating Time Phase C
21E9
Breaker 1 Operating Time
21EA
...Repeated for module number 2
Breaker Arcing Current Actuals (Read Only Non-Volatile) (6 modules)
21EE
...Repeated for module number 2
Breaker Arcing Current Actuals (Read Only Non-Volatile) (6 modules)
21F0
...Repeated for module number 2
Breaker Arcing Current Actuals (Read Only Non-Volatile) (6 modules)
21F2
...Repeated for module number 2
Breaker Arcing Current Actuals (Read Only Non-Volatile) (6 modules)
21FA
...Repeated for module number 3
21FE
...Repeated for module number 4
2208
...Repeated for module number 5
2212
...Repeated for module number 6
Breaker Arcing Current Commands (Read/Write Command) (6 modules)
2224
Breaker 1 Arcing Current Clear Command
2225
Breaker 2 Arcing Current Clear Command
2226
Breaker 3 Arcing Current Clear Command
2227
Breaker 4 Arcing Current Clear Command
2228
Breaker 5 Arcing Current Clear Command
2229
Breaker 6 Arcing Current Clear Command
Passwords Unauthorized Access (Read/Write Command)
2230
Reset Unauthorized Access
Fault Location (Read Only) (5 modules)
2340
Fault 1 Prefault Phase A Current Magnitude
2342
Fault 1 Prefault Phase A Current Angle
2343
Fault 1 Prefault Phase B Current Magnitude
2345
Fault 1 Prefault Phase B Current Angle
2346
Fault 1 Prefault Phase C Current Magnitude
2348
Fault 1 Prefault Phase C Current Angle
2349
Fault 1 Prefault Phase A Voltage Magnitude
234B
Fault 1 Prefault Phase A Voltage Angle
234C
Fault 1 Prefault Phase B Voltage Magnitude
234E
Fault 1 Prefault Phase B Voltage Angle
234F
Fault 1 Prefault Phase C Voltage Magnitude
2351
Fault 1 Prefault Phase C Voltage Angle
2352
Fault 1 Phase A Current Magnitude
2354
Fault 1 Phase A Current Angle
2355
Fault 1 Phase B Current Magnitude
B-16
RANGE
0 to 4294967295
0 to 4294967295
0 to 1
0 to 2
---
0 to 99999999
0 to 99999999
0 to 99999999
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
L90 Line Current Differential System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F300
---
1
F300
---
1
F102
---
1
F109
---
---
F001
2
kA
-cyc
1
F060
2
kA
-cyc
1
F060
2
kA
-cyc
1
F060
ms
1
F001
ms
1
F001
ms
1
F001
ms
1
F001
---
1
F126
---
1
F126
---
1
F126
---
1
F126
---
1
F126
---
1
F126
---
1
F126
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
DEFAULT
0
0
0 (Disabled)
0 (Self-Reset)
0
0
0
0
0
0
0
0
0 (No)
0 (No)
0 (No)
0 (No)
0 (No)
0 (No)
0 (No)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0