GE L90 Instruction Manual page 652

Ur series line current differential system
Hide thumbs Also See for L90:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 14 of 71)
ADDR
REGISTER NAME
Security Reserved Modbus Registers (Read Only)
3375
Address 0x3374 reserved for serial logout
Event recorder actual values (read only)
3400
Events Since Last Clear
3402
Number of Available Events
B
3404
Event Recorder Last Cleared Date
Event recorder commands (read/write)
3406
Event Recorder Clear Command
DCMA Input Values (Read Only) (24 modules)
34C0
DCMA Inputs 1 Value
34C2
DCMA Inputs 2 Value
34C4
DCMA Inputs 3 Value
34C6
DCMA Inputs 4 Value
34C8
DCMA Inputs 5 Value
34CA
DCMA Inputs 6 Value
34CC
DCMA Inputs 7 Value
34CE
DCMA Inputs 8 Value
34D0
DCMA Inputs 9 Value
34D2
DCMA Inputs 10 Value
34D4
DCMA Inputs 11 Value
34D6
DCMA Inputs 12 Value
34D8
DCMA Inputs 13 Value
34DA
DCMA Inputs 14 Value
34DC
DCMA Inputs 15 Value
34DE
DCMA Inputs 16 Value
34E0
DCMA Inputs 17 Value
34E2
DCMA Inputs 18 Value
34E4
DCMA Inputs 19 Value
34E6
DCMA Inputs 20 Value
34E8
DCMA Inputs 21 Value
34EA
DCMA Inputs 22 Value
34EC
DCMA Inputs 23 Value
34EE
DCMA Inputs 24 Value
RTD Input Values (Read Only) (48 modules)
34F0
RTD Input 1 Value
34F1
RTD Input 2 Value
34F2
RTD Input 3 Value
34F3
RTD Input 4 Value
34F4
RTD Input 5 Value
34F5
RTD Input 6 Value
34F6
RTD Input 7 Value
34F7
RTD Input 8 Value
34F8
RTD Input 9 Value
34F9
RTD Input 10 Value
34FA
RTD Input 11 Value
34FB
RTD Input 12 Value
34FC
RTD Input 13 Value
34FD
RTD Input 14 Value
34FE
RTD Input 15 Value
34FF
RTD Input 16 Value
3500
RTD Input 17 Value
3501
RTD Input 18 Value
3502
RTD Input 19 Value
3503
RTD Input 20 Value
B-22
RANGE
0 to 5
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
-32768 to 32767
L90 Line Current Differential System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F617
---
1
F003
---
1
F003
---
1
F050
---
1
F126
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
°C
1
F002
DEFAULT
3 (Engineer)
0
0
0
0 (No)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents