Memory Mapping; Modbus Memory Map - GE L90 Instruction Manual

Ur series line current differential system
Hide thumbs Also See for L90:
Table of Contents

Advertisement

APPENDIX B
B.4MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 1 of 71)
ADDR
REGISTER NAME
Product Information (Read Only)
0000
UR Product Type
0002
Product Version
0003
Boot Configuration Register
Product Information (Read Only -- Written by Factory)
0010
Serial Number
0020
Manufacturing Date
0022
Modification Number
0040
Order Code
0090
Ethernet MAC Address
0093
Reserved (13 items)
00A0
CPU Module Serial Number
00B0
CPU Supplier Serial Number
00C0
Ethernet Sub Module Serial Number (8 items)
Product Information (Read Only -- Written by Factory)
0110
FPGA Version
0113
FPGA Date
Self Test Targets (Read Only)
0200
Self Test States (4 items)
Front Panel (Read Only)
0208
LED Column n State, n = 1 to 10 (10 items)
0220
Display Message
0248
Last Key Pressed
Keypress Emulation (Read/Write)
0280
Simulated keypress -- write zero before each keystroke
Virtual Input Commands (Read/Write Command) (64 modules)
0400
Virtual Input 1 State
0401
Virtual Input 2 State
0402
Virtual Input 3 State
0403
Virtual Input 4 State
0404
Virtual Input 5 State
0405
Virtual Input 6 State
0406
Virtual Input 7 State
0407
Virtual Input 8 State
0408
Virtual Input 9 State
0409
Virtual Input 10 State
040A
Virtual Input 11 State
040B
Virtual Input 12 State
040C
Virtual Input 13 State
040D
Virtual Input 14 State
040E
Virtual Input 15 State
040F
Virtual Input 16 State
0410
Virtual Input 17 State
0411
Virtual Input 18 State
0412
Virtual Input 19 State
0413
Virtual Input 20 State
0414
Virtual Input 21 State
0415
Virtual Input 22 State
0416
Virtual Input 23 State
GE Multilin
RANGE
0 to 65535
0 to 655.35
0 to 65535
---
0 to 4294967295
0 to 65535
---
---
---
---
---
---
---
0 to 4294967295
0 to 4294967295
0 to 65535
---
0 to 47
0 to 46
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
L90 Line Current Differential System
B.4 MEMORY MAPPING
B.4.1 MODBUS MEMORY MAP
UNITS
STEP
FORMAT
---
1
F001
---
0.01
F001
---
1
F001
---
---
F203
---
1
F050
---
1
F001
---
---
F204
"Order Code x"
---
---
F072
---
---
F001
---
---
F203
---
---
F203
---
---
F203
---
---
F206
--
1
F050
0
1
F143
---
1
F501
---
---
F204
---
1
F530
---
1
F190
0 (No key -- use
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F108
DEFAULT
0
B
1
0
"0"
0
0
0
0
(none)
(none)
(none)
(none)
0
0
0
(none)
0 (None)
between real
keys)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Off)
B-9