GE L90 Instruction Manual page 621

Ur series line current differential system
Hide thumbs Also See for L90:
Table of Contents

Advertisement

APPENDIX A
Table A–1: FLEXANALOG DATA ITEMS (Sheet 7 of 14)
ADDRESS
FLEXANALOG NAME
7288
SRC 4 PF
7289
SRC 4 Phase A PF
7290
SRC 4 Phase B PF
7291
SRC 4 Phase C PF
7552
SRC 1 Frequency
7554
SRC 2 Frequency
7556
SRC 3 Frequency
7558
SRC 4 Frequency
7680
SRC 1 Demand Ia
7682
SRC 1 Demand Ib
7684
SRC 1 Demand Ic
7686
SRC 1 Demand Watt
7688
SRC 1 Demand var
7690
SRC 1 Demand Va
7696
SRC 2 Demand Ia
7698
SRC 2 Demand Ib
7700
SRC 2 Demand Ic
7702
SRC 2 Demand Watt
7704
SRC 2 Demand var
7706
SRC 2 Demand Va
7712
SRC 3 Demand Ia
7714
SRC 3 Demand Ib
7716
SRC 3 Demand Ic
7718
SRC 3 Demand Watt
7720
SRC 3 Demand var
7722
SRC 3 Demand Va
7728
SRC 4 Demand Ia
7730
SRC 4 Demand Ib
7732
SRC 4 Demand Ic
7734
SRC 4 Demand Watt
7736
SRC 4 Demand var
7738
SRC 4 Demand Va
9024
Prefault Ia Mag [0]
9026
Prefault Ia Ang [0]
9027
Prefault Ib Mag [0]
9029
Prefault Ib Ang [0]
9030
Prefault Ic Mag [0]
9032
Prefault Ic Ang [0]
9033
Prefault Va Mag [0]
9035
Prefault Va Ang [0]
9036
Prefault Vb Mag [0]
9038
Prefault Vb Ang [0]
9039
Prefault Vc Mag [0]
9041
Prefault Vc Ang [0]
9042
Postfault Ia Mag [0]
9044
Postfault Ia Ang [0]
9045
Postfault Ib Mag [0]
GE Multilin
UNITS
DESCRIPTION
---
Source 4 three-phase power factor
---
Source 4 phase A power factor
---
Source 4 phase B power factor
---
Source 4 phase C power factor
Hz
Source 1 frequency
Hz
Source 2 frequency
Hz
Source 3 frequency
Hz
Source 4 frequency
Amps
Source 1 phase A current demand
Amps
Source 1 phase B current demand
Amps
Source 1 phase C current demand
Watts
Source 1 real power demand
Vars
Source 1 reactive power demand
VA
Source 1 apparent power demand
Amps
Source 2 phase A current demand
Amps
Source 2 phase B current demand
Amps
Source 2 phase C current demand
Watts
Source 2 real power demand
Vars
Source 2 reactive power demand
VA
Source 2 apparent power demand
Amps
Source 3 phase A current demand
Amps
Source 3 phase B current demand
Amps
Source 3 phase C current demand
Watts
Source 3 real power demand
Vars
Source 3 reactive power demand
VA
Source 3 apparent power demand
Amps
Source 4 phase A current demand
Amps
Source 4 phase B current demand
Amps
Source 4 phase C current demand
Watts
Source 4 real power demand
Vars
Source 4 reactive power demand
VA
Source 4 apparent power demand
Amps
Fault 1 pre-fault phase A current magnitude
Degrees
Fault 1 pre-fault phase A current angle
Amps
Fault 1 pre-fault phase B current magnitude
Degrees
Fault 1 pre-fault phase B current angle
Amps
Fault 1 pre-fault phase C current magnitude
Degrees
Fault 1 pre-fault phase C current angle
Volts
Fault 1 pre-fault phase A voltage magnitude
Degrees
Fault 1 pre-fault phase A voltage angle
Volts
Fault 1 pre-fault phase B voltage magnitude
Degrees
Fault 1 pre-fault phase B voltage angle
Volts
Fault 1 pre-fault phase C voltage magnitude
Degrees
Fault 1 pre-fault phase C voltage angle
Amps
Fault 1 post-fault phase A current magnitude
Degrees
Fault 1 post-fault phase A current angle
Amps
Fault 1 post-fault phase B current magnitude
L90 Line Current Differential System
A.1 PARAMETER LISTS
A-7
A

Advertisement

Table of Contents
loading

Table of Contents