5-9 Selecting the setting data

5-9-1 Speed setting

(1) Speed setting selection

The speed setting in VAT2000 is possible from either analog input signals, or from host computer or
from the operation panel. There are a total of nine different setting, all selectable.
Setting
input point
Analog
Analog speed setting 1
Analog speed setting 2
Analog speed setting 3
Serial or
Serial speed setting
parallel
Parallel speed setting
Operation
Speed setting
panel
Panel jogging setting
Traverse operation
Pattern Run operation

(2) Speed setting selection sequence

The ratio of the speed setting (Ratio Interlock) and sequence control for signals is shown below.
Refer to Section 6-5, B06 (Ratio interlock setting) for details.
A n alog spe e d settin g 3
(C 0 7-2 )
A n alog spe e d settin g 2
(C 0 7-1 )
A n alog spe e d settin g 1
(C 0 7-0 )
O pe ra tio n P an e l freq ue ncy
(o r s pe ed ) settin g
(A 0 0- 0, 2)
S e ria l co m m u nica tion
spe ed settin g
Tra ve rse freq u en cy
(o r s pe ed ) settin g
(B 4 4- 0 to 6 )
P ro gr am fre q ue ncy
(o r s pe ed ) settin g
(B 11 -0 to 7)
P a ne l Jo g se tting
(A 0 0- 1, 3)
P a te rn R un fre qu en cy
(o r s pe ed ) settin g
(B 5 0- 0 to B 59 -3)
5. Control Input / Output
Setting data
The speed setting is possible from either of three analog
inputs provided as standard in the VAT2000.
The speed setting is allowed from a host computer, through
the programmer port or using the serial interface option
U2KV23SL0, or optional Profibus DP interface.
The speed setting is allowed from a host PLC with parallel
transmission. A PC interface option type U2KV23PI0 is
required.
The speed setting is allowed by parameter (A00-0 or 2).
The speed setting is allowed by parameter (A00-1, 3).
The speed setting is allowed by parameters (B44-0 to 6), when
the "Traverse" function is enabled.
The speed setting is allowed by parameters (B50-0 to B59-3),
when the Pattern Run function is enabled
R a tio In te rlo ck
A X + B + C
R a tio In te rlo ck
A X + B + C
R a tio In te rlo ck
o n
o n
A X + B + C
o ff
o ff
V F S
R a tio In te rlo ck
A X + B + C
o n =4
o ff= 4
B 4 0-0
Fig. 5-9 Speed setting selection
Explanation
Fu n ction s tha t can b e c o ntrolled O N / O FF
X X X
from te rm inal b oard
o n
o ff
A U X
IF S
P R O G
C F S
JO G
o n
o ff
o ff
o ff
o n
o n
5-14
C 0 2-0
o n
o ff
B 4 0-0
C 3 0-0
o ff= 3
o ff= 1 ,2
o n =3
o n =3 ,4 ,5
R F O
o ff
o n
0
S p ee d
setttin g
=1
=2
=3
=4
L C L